Disturbances in The Power Supply Network of Bucharest Subway System 1231.6. Behaviour of Closed Circuit TV (CCTV) equipmenta) Electromagnetic disturbances of frequencies between 50 Hz-50 MHz penetrateall equipment of the subway system;b) The strongest penetration is observed through the CCTV cable (double shiel<strong>de</strong>dcable) - because along the tunnel there are variable potentials and the cables donot meet the terms of the level of insulation - since it takes over as the variationof variable potentials along the tunnel;c) In the CCTV cable, insulation breakthrough occurs, changes in insulatio<strong>nr</strong>esistance and electrical resistance, as well;d) Inductive coupling of screen with wire insi<strong>de</strong> creates low impedance for thereturn current through the screen (the disruptive route);e) Connecting the screen to earth (tunnel - with variable potentials) forces thedisruptive current returns from the central wire through the screen.1.7. Preliminary ConclusionsUsing Fluke <strong>de</strong>vices, in the work we have established new measurementmethodologies, we checked them and realized measurement result analysis. Theyled to the following conclusions:- Have established the precise conditions of operation of upgra<strong>de</strong>d tractio<strong>nr</strong>ectifier RSTM - 0825M;- Have set the effect of electric traction substations of the electrical company’spower system. To <strong>de</strong>fine solutions for admission to the technical norms, therewere <strong>de</strong>termined the short-circuit currents and characteristics of the electricalcompany’s 110 kV / MV power network;- Have <strong>de</strong>fined technical solutions to framing into technical regulations foroperation un<strong>de</strong>r <strong>de</strong>forming system and load shock throughout the SubwayLine II;- Have established the causes and nature of disturbances that occur in the closedcircuit television system at the central dispatch of the Unirii 1 station. Todiminishing that, the runway insulation needs to be improved, subway frameoptimized and properly maintained as well.Copyright © Editura Aca<strong>de</strong>miei <strong>Oamenilor</strong> <strong>de</strong> Știință <strong>din</strong> România, <strong>2011</strong>Watermark Protected

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!