12.07.2015 Views

Unit III - Sanitary Sewer Design Standards - City of Fort Wayne

Unit III - Sanitary Sewer Design Standards - City of Fort Wayne

Unit III - Sanitary Sewer Design Standards - City of Fort Wayne

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Water Resources Development Criteria/<strong>Standards</strong> Manual Chapter 4UNIT <strong>III</strong> - <strong>Sanitary</strong> <strong>Sewer</strong> <strong>Design</strong> <strong>Standards</strong>Building <strong>Sewer</strong>s4.6 Hydraulic <strong>Design</strong> Criteria4.6.1 Plumbing CodesBuilding sewers shall conform to the latest adopted version <strong>of</strong> the Uniform PlumbingCode. As an alternative to plumbing codes, an engineer licensed in the state <strong>of</strong> Indianamay design a building sewer.4.6.2 Minimum SlopesBuilding sewers shall be laid on a minimum slope <strong>of</strong> 2.08% (1/4” per foot). Anyexception to this must be approved by Water Resources.4.7 Building <strong>Sewer</strong> Connection to Public <strong>Sewer</strong>The building sewer shall connect to the public sewer at a mainline fitting. The building sewershall not protrude into the main line.Connections to manholes must receive prior approval from Water Resources. Inside dropconnections to the manhole will not be permitted. When connections are made to manholestructures, rubber water stop joints or mortared rubber gaskets (boots) poured in place shall bespecified for water tightness between the pipe and the manhole. When new holes into manholesare required, core drilling <strong>of</strong> the new hole shall be specified.Building sewer installed for future connections shall be terminated at the street right-<strong>of</strong>- way oreasement and shall be properly plugged with a manufactured plug to ensure a watertight seal. Aone-half inch ferrous locator rod or a magnetic locator tape shall be installed at the plugged lineto within one foot (1’) <strong>of</strong> the finished grade.4.8 Building <strong>Sewer</strong> Structures4.8.1 CleanoutsA cleanout shall be provided adjacent to all building structures. The maximum distancebetween the exterior building wall and the cleanout wye shall be seven feet (7’).4.8.2 Grease and Sand TrapsAny building sewer which will have or has the potential <strong>of</strong> discharging waste containinggrease, oil, sand, or similar substances, having quantity and characteristics above that <strong>of</strong> anormal single family residence waste, shall have a grease and/or sand trap installed in amanner to provide, at all times, the effective removal <strong>of</strong> grease, oil, sand, and/or similarsubstances before discharge to the public sewer.Installation <strong>of</strong> a grease and/or sand trap will be required within a building sewer whenany one <strong>of</strong> the following conditions exist:• Abnormal maintenance <strong>of</strong> the sewer has been required to prevent the occurrence <strong>of</strong>blockages, back-ups, etc., resulting in property damage; and evidence indicates thatCreated: January 1, 2002 <strong>III</strong> - 4 - 4 <strong>City</strong> <strong>of</strong> <strong>Fort</strong> <strong>Wayne</strong>Revised:

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!