12.07.2015 Views

8 MB - POWERLAB

8 MB - POWERLAB

8 MB - POWERLAB

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Functionsand characteristicsCircuit breakersand switch-disconnectors 0NT06 to NT16PB100767-48Common characteristicsNumber of poles 3/4Rated insulation voltage (V) Ui 1000Impulse withstand voltage (kV) Uimp 12Rated operational voltage (V AC 50/60 Hz) Ue 690/1000Suitability for isolation IEC 60947-2Degree of pollution IEC 60664-1 3Circuit-breaker characteristics as per IEC 60947-2Rated current (A) In at 40 °C/50 °C (1)Rating of 4th pole (A)Sensor ratings (A)Type of circuit breakerUltimate breaking capacity (kA rms) Icu 220/415 VV AC 50/60 Hz440 V525 V690 V1000 VRated service breaking capacity (kA rms) Ics % IcuUtilisation categoryRated short-time withstand current (kA rms)V AC 50/60 HzIcw0.5 s1 s3 sIntegrated instantaneous protection (kA peak ±10 %)Rated making capacity (kA peak) Icm 220/415 VV AC 50/60 Hz440 V525 V690 V1000 VBreak time (ms) between tripping order and arc extinctionClosing time (ms)Circuit-breaker characteristics as per NEMA AB1Breaking capacity (kA)V AC 50/60 Hz240 V480 V600 V(1) 50 °C: rear vertical connected. Refer to temperaturederating tables for other connection types.(2) See the current-limiting curves in the "additionalcharacteristics" section.(3) SELLIM system.(4) Available for 480 V NEMA.(5) Suitable for motor control (direct-on-line starting).Switch-disconnector characteristics as per IEC 60947-3 and Annex AType of switch-disconnectorRated making capacity (kA peak) Icm 220 VAC23A/AC3 category V AC 50/60 Hz440 V525/690 V1000 VRated short-time withstand current (kA rms) Icw 0.5 sAC23A/AC3 category V AC 50/60 Hz1 s3 sUltimate breaking capacity Icu (kA rms) with an external protection relay 690 VMaximum time delay: 350 msMechanical and electrical durability as per IEC 60947-2/3 at In/IeService life Mechanical with maintenanceC/O cycles x 1000without maintenanceType of circuit breakerIn (A)Rated currentC/O cycles x 1000 Electrical without maintenance 440 V (4)IEC 60947-2690 V1000 VType of circuit breaker or switch-disconnector Ie (A)Rated operationnal currentAC23AC/O cycles x 1000 Electrical without maintenance 440 V (4)IEC 60947-3690VType of circuit breaker or switch-disconnector Ie (A)Rated operationnal current AC3 (5)Motor power380/415 V (kW)440 V (kW)C/O cycles x 1000 Electrical without maintenance 440 V (4)IEC 60947-3 Annex M/IEC 60947-4-1690 V18

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!