Linear actuators AC versions<strong>CAT</strong> 32BSuitable control units and accessoriesDimensional drawingSee drawings of front and rear attachmentsand motor options on page 286. Cover for brake104154CAEV 110/220CAXB 32B 1)E2 2)†8<strong>01</strong>08 5<strong>02</strong><strong>01</strong>823E110CE110CBE220CE220CBE380CCAES 31CLegend:S = strokeL = retracted lengthL= S+ (167/175/206)*1) See page 3952) See page 396 Dimension depends on selected front attachment*5723 2473120 or 230 V ACmotor400 V ACmotorConnecting diagrams120/230 V ACL1NPECW0CCW400 V ACL1L2L3NPEQ1Q2Q2BlackBlueWhiteBrownRedRedQ2Q1Q1Black1Black2LimitswitchLimitswitchW1 V1 U1M3Technical dataUnit <strong>CAT</strong> 32BPush load N 1 500 to 3 500Pull load N 1 500 to 3 500Speed (at full load) mm/s 6,5 to 32 1)Stroke mm 50 to 700Retracted length mm S+167/175/206 2)Voltage V AC 120, 230 or 400Power consumption 120 V AC W 98 (brake 133,2 W)230 V AC W 92 (brake 117,3 W)400 V AC W 80Current consumption 120 V AC A 0,82 (brake +0,29 A)230 V AC A 0,4 (brake + 0,11 A)400 V AC A 0,2Duty cycle % 30Ambient temperature °C –20 to +50Type of protection IP 20/54/55Weight kg 2 to 3,51) Depending on selected motor2) Dimension depends on selected front attachment157