Linear actuators DC versionsCAJA 60Suitable control units and accessoriesDimensional drawing130,619,5†10,2?0,1/†12,2?0,1114,314†10,2?0,1/†12,2?0,122CAJC 41L=S+17042,2 59,3†70,13CAJA 60CAJH 137,7CAJF 17,1144,62574,517,536†288,2±0,1Connecting diagram33,925,524 V DC+-+5VGNDHall AHall B8,25432,793,71+7Blue1+7Red3 5 6 8 DIN 8plug†10,2?0,1/†12,2?0,134MNCActuatorNC2 Hallsensors signalHall AHall BLegend:S = strokeL = retracted length14Technical dataUnit CAJA 60Push load N 6 000Pull load N 4 000Speed (full load to no load) mm/s 4,6 to 7,8Stroke mm 30 to 300Retracted length 1) mm S+170 2)Voltage V DC 24–41Power consumption W N/ACurrent consumption A 4,5Duty cycle % 10Ambient temperature °C +10 to +40Type of protection IP 54Weight (at 300 mm stroke) kg 2,5Color – Grey1) Tolerance +/-3 mm2) Retracted length +3 mm if U fork used as front attachment (L= S+183)195