Linear actuators DC versionsCAJA 35CSuitable control units and accessoriesDimensional drawing130,619,5†10,2?0,1/†12,2?0,1114,314†10,2?0,1/†12,2?0,122L=S+180/18342,259,3CAJC 41†70,13CAJA 35CCAJH 1CAJF 137,77,155,2144,62574,517,536†288,2?0,1Connecting diagram47,525,556724 V DC+-+5VGNDHall AHall B5 4Bowden CPR cable connection: M6, 10 mm474,432,78,293,71+7Blue1+7Red3 5 6 8 DIN 8plug†10,2?0,1/†12,2?0,134MNCActuatorNC2 Hallsensors signalHall AHall BLegend:S = strokeL = retracted length14Technical dataUnit CAJA 35CPush load N 3 500Pull load N 3 500Speed (full load to no load) mm/s 7,5 to 10,5Stroke mm 30 to 250Retracted length 1) mm S+180 2)Voltage V DC 24-41Power consumption W N/ACurrent consumption A 4Duty cycle % 10Ambient temperature °C +10 to +40Type of protection IP 54Weight (at 250 mm stroke) kg 2,5Color – Grey1) Tolerance +/-3 mm2) Retracted length +3 mm if U fork used as front attachment (L= S+183)235