12.07.2015 Views

Heater Catalog - Watlow

Heater Catalog - Watlow

Heater Catalog - Watlow

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Immersion <strong>Heater</strong>sWATROD and FIREBAR ANSI FlangeImmersion <strong>Heater</strong>sFeatures and Benefits (Continued)FIREBAR flange heaters pack more kilowatts into asmaller bundle• Includes a conventional round tubular 10 in. (254 mm)ANSI flange which can be replaced by a 6 in.(152 mm) ANSI FIREBAR flange with the sameimmersed lengthBranch circuits are designed for 48 amperes percircuit maximum• Reduces risk of failure due to excessive temperaturesgenerated by high amperageUL ® and CSA component recognition under filenumbers E52951 and 31388 respectively• Simplifies obtaining third-party recognition forassemblyTypical Applications• Water:DeionizedDemineralizedCleanPotableProcess• Industrial water rinse tanks• Vapor degreasers• Hydraulic oil, crude, asphalt• Lubricating oils at API specified watt densities• Air and gas flow• Caustic solutions• Chemical baths• Process air equipment• Boiler equipment• Freeze protection of any fluid• Anti-freeze (glycol) solutions• ParaffinOptionsTerminal EnclosuresGeneral purpose terminal enclosures, withoutthermostats, are standard on all flange immersionheaters. Optional terminal enclosures include:• General purpose with a single or double polethermostat.• Moisture resistant. Available with or without a singleor double pole thermostat.• Corrosion resistant. Available with or without a singleor double pole thermostat.• Explosion resistant Class 1, Div. 1 and 2, Groups B, C,D, T1 - T6. Available with or without a single or doublepole thermostat.• Explosion/moisture resistant combinations. Availablewith or without a single or double polethermostat.Prior to ordering, refer to the terminal enclosuredimensions on page 243. Order by adding theappropriate suffix letter(s) to the base flange heaterpart number, as shown on the Ordering information chart.<strong>Heater</strong> part numbers and suffix letters are depicted onthe charts, pages 244 to 305. Specify class and group,if applicable.CautionExplosion-resistant terminal enclosures are intendedto provide explosion containment in the electricaltermination/wiring enclosure only. No portion of theassembly outside of this enclosure is covered underthis rating. Rating effectiveness may be compromisedby abuse or misapplication.238WATLOW ®

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!