12.07.2015 Views

Heater Catalog - Watlow

Heater Catalog - Watlow

Heater Catalog - Watlow

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Air <strong>Heater</strong>sDuct <strong>Heater</strong>sLDH SERIES and D SERIESPressure Drop vs. Air VelocityThe rate at which pressure drops through the duct heateris critical for properly sizing blowers and pumps. ThePressure Drop vs. Air Velocity graph gives recommendedmaximum velocities in feet per minute and meters perminute according to the air velocity and duct heater size.To determine the pressure drop through the duct heater,follow the air velocity (FPM or MPM) over to theappropriate curve, which identifies the duct heatersize. Then, take the intersecting point down to theapproximate pressure drop value.Air Flow for ≥ 24kWThermowell6kW9kW12kW18kWAir flow for6 to 18kW>18kWNote: Viewing from the element ends—therecommended air flow direction throughelement bundle changes at >18kW.Air Velocity—FPM20001900180017001600150014001300120011001000900800700600500400300200100Round Tubular Duct <strong>Heater</strong> D6Round and FIREBAR Tubular Duct <strong>Heater</strong>sPressure Drop vs. Air VelocityRound Tubular Duct <strong>Heater</strong> D12Round Tubular Duct <strong>Heater</strong> D18Round Tubular Duct <strong>Heater</strong> D24 - D125®FIREBAR Duct <strong>Heater</strong> of Equivalent kW is 30%the Pressure Drop of a Round Tubular Duct <strong>Heater</strong> 1Air Velocity—MPM80075070065060055050045040035030025020015010050Round and FIREBAR Tubular Duct <strong>Heater</strong>sPressure Drop vs. Air VelocityRound Tubular Duct <strong>Heater</strong> D6Round Tubular Duct <strong>Heater</strong> D12Round Tubular Duct <strong>Heater</strong> D18Round Tubular Duct <strong>Heater</strong> D24 - D125®FIREBAR Duct <strong>Heater</strong> of Equivalent kW is 30%the Pressure Drop of a Round Tubular Duct <strong>Heater</strong> 10.020.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 0.20Approximate Pressure Drop—Inches of Water0.0050.010 0.015 0.020 0.025 0.030 0.035 0.040 0.045 0.050Approximate Pressure Drop—Kilopascals1 FIREBAR ® flat tubular element duct heaters are available as extended capabilities to enhance your application output or performance. Although ductheaters are not normally constructed with FIREBAR elements, the pressure drop reduction using FIREBAR as a distinct advantage is shown above.OptionsWattages/VoltagesTo meet specific application needs, voltage and wattagecombinations outside stock product parametersare available.For more information about this option, contact your<strong>Watlow</strong> representative.394 WATLOW ®

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!