Environmental Impact Assessment Study for <strong>400</strong> <strong>kV</strong> OHL SS Stip – Macedonian-Serbian BorderThe basic technical paramteres of the transmission line are presented in the following table:Table – Review of technical parameters of the <strong>400</strong> <strong>kV</strong> interconnection transmission lineParameterCharacteristicNominal voltage <strong>400</strong> <strong>kV</strong>Type of towers Steel-bar hot zinc-coated, with horizontally placed conductors, two per phaseand two protective wiresFoundationTypical solutions, depending on the engineering and geo-mechanicalparameters of the ground.Reinforced concrete - brand of concrete acording to the valid regulations.Protection against corrosion of anchor segment, 50 cm above the level of theterrain.Conductor √ Number per phases: 2√ Material: AlFe√ Section: 490/65 mm 2Protective wire√ Maximum work strain: According to valid regulationsTwo earth-lead wires in horizontal lowland:• First: Alumoweld hawser with diameter of 126.1 mm 2 , labeled AWG 19/9• Second: Protective hawser with optic fiber, OPGW with 48 fibers(Mechanical and electric characteristics will correspond to classic protectivehawser)Insulators • Type of insulator:- On the line: Phase, massive, porcelain insulator of the type75/21+20=160 or glass hanging insulators U-160- On the portal: Glass hanging, of the type U-160• Type of insulator chain: According to the regulationsEarthing of towers • Specific resistance of the ground: According to the terrain measurementsof specific places and use of typical earthing• Material: Circular zinc-coated steel• Dimensions: Minimum diameter ∅10 mmConnective equipment Connective materials for the planned insulators are hot zinc-coated.Climate parameters √ Wind pressure: 75 daN/m 2√ Burden from ice and snow: 1,6 x 0,18√d daN/m 2√ External temperature:- Maximum + 40 °С- Minimum - 20 °СSafety hightAt least 1 m higher than the prescribed in the Regulation, as a result oftiredness of the materials, intensive construction of near-by facilities, use ofagricultural machinery, etc.2.3.1 TowersAccording to the current concept in Macedonia, all single <strong>400</strong> <strong>kV</strong> power transmission lineshave been constructed by connecting two conductors per phase and symetrically positionedcables. Prusuant to the aforementioned and based on the practices and experience to date,<strong>400</strong> <strong>kV</strong> transmission lines are constructed of steel bars hot zinc-coated with horizontallyplaced conductors and protective wires in the form of the letter "Y”. This means that thetowers for the <strong>400</strong> <strong>kV</strong> cross-border transmission line between Macedonian and Serbia willmeet the following basic technical and technological conditions:43

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!