13.07.2015 Views

INSTALLATION MANUAL

INSTALLATION MANUAL

INSTALLATION MANUAL

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

167187-UIM-B-0306AC10 2 Stage Scroll A/C w/ Variable Speed Furnace - PV8/9; (F,L)*8/9V, (G,L)*8/9V, XYG80V-U, XYF80V-U / XYF80V-U*LTHERMOSTAT*DN22U00124C24-Volt CommonYFirst Stage CoolY2Second Stage CoolR24-Volt Hot (Heat XFMR)RC24-Volt Hot (Cool XFMR)E/W1First Stage HeatW2Second Stage HeatGFanTHERMOSTAT*PP32U70124C24-Volt CommonYFirst Stage CoolY2Second Stage CoolR24-Volt Hot (Heat XFMR)RC24-Volt Hot (Cool XFMR)E/W1First Stage HeatW2Second Stage HeatGFanTHERMOSTAT*DN22C00124C24-Volt CommonYFirst Stage CoolY2Second Stage CoolR24-Volt HotWFirst Stage HeatW2Second Stage HeatGFanTHERMOSTAT*DP22U70124C24-Volt CommonY1First Stage CoolY2Second Stage CoolR24-Volt HotE/W1First Stage HeatW2Second Stage HeatGFanTHERMOSTAT*PP32U71124*PP32U72124C24-Volt CommonY1First Stage CoolY2Second Stage CoolR24-Volt HotE/W1First Stage HeatW2Second Stage HeatGFanDHMDehumidistatLMalfunction LightHMHumidistatConnection of the "C"Termainal, 24-VoltCommon, is optionalwhen used with batteriesConnection of the "C"Termainal, 24-VoltCommon, is optionalwhen used with batteriesConnection of the "C"Termainal, 24-Volt Common,is optionalwhen used with batteriesConnection of the "C" Termainal,24-VoltCommon, is optionalwhen used with batteriesStep 1 of Thermostat UserConfiguration Menu must beset to MLTI STGThermostat Installer SetupNumber 1 - System Type -must be set to 6 - 2Heat/2 Cool ConventionalThermostat InstallerSetup Number 0170 -System Type - must beset to 8 - 2 Heat/2 CoolMultistage ConventionalStep 1 of Thermostat UserConfiguration Menumust be set to MS 2Step 16 of ThermostatUser Configuration Menumust be set to ON to useComfort Alert FeaturesThermostat Installer SetupNumber 15 - CompressorProtection - must be set to 5E2/P Switch must be inthe E2 position and theHumidistat Jumper onCFM Control must bein the 'YES' positionfor DehumidificationVARIABLE SPEEDFURNACE CONTROLC24-Volt CommonY1First Stage CoolY/Y2Single/Second Stage CoolR24-Volt HotW/W1Single/First Stage HeatW2Second Stage HeatGFanCFM CONTROLHUMDehumidification - Open on Humidity Rise(O)Reversing Valve– Energized in Cool(X/L)Malfunction Light( ) CONVENIENCE TERMINALNO FUNCTION IN THIS APPLICATION.TWO STAGEAIR CONDITIONINGC24-Volt CommonY1First Stage CoolY2Second Stage CoolR24-Volt HotComfort AlertInterface24V HUMIDIFIER(Optional)FIGURE 10: Thermostat Chart - ACUnitary Products Group 11

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!