CONFIGURING THE UPSThe following table shows all possible configurations available to tailor the UPS to your needs in the best way possible.CP (Control Panel) =SW (Software) =Indicates that the configuration can be edited not only by the configuration software but also using thecontrol panel (if function editing is enabled on the panel).Indicates that the configuration can be changed from the configuration software only.FUNCTION DESCRIPTION DEFAULT POSSIBLE CONFIGURATIONS MOD.Output frequencyOutput VoltageSelecting the rated outputfrequency (for the setting tobe active, turn the UPS offthen back on)Selects nominal Outputvoltage (Phase / Neutral)50 Hz230V• 50 Hz• 60 Hz• 200V *• 208V *• 220V• 230V• 240VCPCP• 220 ÷ 240 in steps of 1VSWOperating ModeSelects one of the 5operating modesON LINE• ON LINE• ECO• SMART ACTIVE• STAND-BY OFFCP• FREQUENCY CONVERTERSW<strong>Power</strong> off due tominimum loadAutomatically switches offthe UPS in battery operationwhen the load is less than5%Disabled• Enabled• DisabledCPAutonomylimitationLow batterypre-alarmBattery testSets the maximum time ofbattery operationSets the estimated autonomytime left for low batterywarningSets the interval of time forthe automatic battery testDisabled3 min.40 hours• Disabled (complete batterydischarge)• 1 ÷ 65000 in steps of 1 sec.1 ÷ 255 in steps of 1 min.(1 to 7 min from the panel)• Disabled/Enabled (from the panel)• 1 ÷ 1000 in steps of 1 hourSWSWSWMaximum loadalarm thresholdSelects the user overloadlimitDisabled• Disabled• 0 ÷ 103 in steps of 1%SWSound alarmSelects the operating modeof the sound alarmReduced• Normal• Reduced: does not sound because ofmomentary intervention of the bypassCPAuxiliary socket(power share)Selects the operating modeof the auxiliary socketAlwaysconnected• Always connected• Disconnected after n seconds ofbattery operation• Disconnected after n seconds from theend-of-discharge alarm signal• ... (see configuration software manual)SWBattery expansionSets the Ah installed(external battery extension)0 AhMin.: 0 - Max.: 999(in steps of 1 Ah)CPLanguage** Selects the display language English• English• Italian• German• French• Spanish• Polish• Russian• ChineseCPDate and time Sets the date and time -- -- CP

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!