13.07.2015 Views

EX500-GPR1

EX500-GPR1

EX500-GPR1

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Wiring ( continued )Power supply wiringConnect the power supply connector cable to the power supply connector of GW unit.There are two types of cables different in connector shape ---- straight type and angletype. With this cable, the power is supplied to the output devices such as solenoid valve,and the input devices such as sensor, and for controlling GW/SI. Therefore, there is noneed to supply the power to other units individually.When selecting the power supply, refer to "Handling precautions" ( page 3 ) in this manual.Cable connectionAligning the key groove with the power supplyconnector ( plug ) of GW unit, plug the power supplycable ( socket ).Tighten the lock nut on cable side by turning itclockwise by hand.Confirm that the connector portion does not move.Separate wiring for power supply for solenoid valves/output andfor input and control of GW/SIBoth single power supply and two power supply systems can be adopted, however, thewiring shall be made separately ( for solenoid valves/output and for input and controllingGW/SI ) for either system.A. Two power supply system24VDC24VDCBrown: 0V ( for solenoid valves/output )White: DC24V ( for solenoid valves/output )Gray: Ground ( PE )Blue: 0V ( for input and controlling GW/SI )Black: DC24V ( for input and controlling GW/SI )Cable Part No. : <strong>EX500</strong>-AP -2513 4Power supplyconnectorPin layout and connection diagram of power supply connector cable for ( unit: mm )( Pin layout and connection diagram are common to all cables. )M1214.91834486M1230 550 31.3Straight connector TypeAngle connector Type<strong>EX500</strong>-AP -S <strong>EX500</strong>-AP -A28.3630 550B. Single power supply systemBrown: 0V ( for solenoid valves/output )White: DC24V ( for solenoid valves/output )Gray: Ground ( PE )24VDCBlue: 0V ( for input and controlling GW/SI )Black: DC24V ( for input and controlling GW/SI )Cable Part No. : <strong>EX500</strong>-AP -2513 4Power supplyconnectorPin No.12345Cable color: Signal nameBrown: 0V ( for solenoid valves/output )White: DC24V+10%/-5% ( for solenoid valves/output )Blue: 0V ( for input and controlling GW/SI )Black: DC24V 10% ( power supply for input and controlling GW/SI )Gray: Ground ( PE )1254 3Socket Connector Pin LayoutNOTEConnect a ground cable of 100 or less to PE terminal.( The Shield and PE terminal of PROFIBUS-DP are connected inside GW unitthrough capacitor. )12 13

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!