<strong>Boulder</strong> <strong>Valley</strong> <strong>School</strong> <strong>District</strong><strong>Educational</strong> <strong>Facilities</strong> <strong>Master</strong> <strong>Plan</strong>Facility Condition Assessment (FCA)The Facility Condition Assessment identified physical deficiencies within the building systems foreach school. These deficiencies may represent items that need repair or are at the end of theirservice life, such as worn carpet or old, inefficient boilers. In addition, deficiencies could includeitems that need to be added to a building, such as air conditioning or security systems. Itemsthat may represent immediate safety or code related issues are dealt with by the <strong>District</strong> in anon-going program.Facility Condition Assessment (FCA) CategoryCategory 1Category 2Category 3Category 4Category 5Category 6Category 7Currently Critical - needsimmediate action to stopdeterioration or correct a hazardPotentially Critical - needs actionwithin 1 to 2 years to preventfurther deteriorationNecessary - Not yet critical - needsaction within 3 to 5 years topreclude deterioration or downtimeRecommended - Items that makea sensible improvement to thefacilityDoes not meet currentcodes/standardsBeyond rated life but stillserviceableHazardous material contained andmanaged in placeExamplesFire alarm improvements, exhaust issues,smoke hatches for stages, intercomimprovements, electrical issues, emergencylights, exit signsElectrical service, electrical distribution,ventilation issues, aged boilers, acousticsissues, irrigation improvements, clock systemimprovements, roofing, surge protection,intercom system, pavingHVAC improvements, site drainage, exteriordoors, exterior lighting, A/C for offices/computerrooms, painting, carpet, VCT, gym flooring,casework, windows, interior doors, replaceoperable walls, replace select exterior wallcomponents, ceilings, roofingFire sprinklers, A/C, plumbing componentenhancements and fixtures, electricalenhancementsADA toilet room improvements, drinkingfountains, and circulation improvementsReplace aged portables, replace interior doorsand hardwareAsbestos abatementCapital Improvement <strong>Plan</strong>ning Committee May 2006 Page 12
<strong>Boulder</strong> <strong>Valley</strong> <strong>School</strong> <strong>District</strong><strong>Educational</strong> <strong>Facilities</strong> <strong>Master</strong> <strong>Plan</strong>Examples of Facility Condition Deficiencies:Missing or damaged ceiling tiles.Older boilers exist throughout the <strong>District</strong>.Structural cracking in support structuresInefficient single pane windowswith aluminum frames.Capital Improvement <strong>Plan</strong>ning Committee May 2006 Page 13