RUV X.X – This display shows the software revision number. (DV units areloaded with variable speed drive.)NR O - Indicates simple operation of unit as a Universal Solar <strong>Differential</strong>Temperature (<strong>USDT</strong>) controller. You may move to next level of sophistication byregistering your unit and having an authorization code. Change this value to 1 foractivation of third sensor.Hysteresis Bandwidth – User can program hysteresis (temperature range foroutput control) by using max?, max=, min=, and min?.max?1 Pump stops above this temperature (T1, T2, T3)max=1 Pump runs below this temperature if other conditions aremet (T1, T2, T3)Note: This feature is useful to protect over heating of storage tank (T2) and inother program version not supported with basic software load.diff=1diff?1Pump runs when temperature difference between collectorT1 (collector) and T2 (tank) exceeds this value. Factorysetting is 15 o F. Consult your collector manufacturer for therecommended value.Pump stops when temperature difference between collectorT1 (collector) and T2 (tank) reaches this value. Factorysetting is 7 o F. Consult your collector manufacturer for therecommended value.11