ParameterizationDialog: StartDialog box: DP Slave PropertiesTab: “Cycle synchronization”Checkbox: “Synchronize drive to equidistant DP cycle”Button: AlignmentDP Slave PropertiesGeneralConfigurationCycle clock synchronizationSynchronize drive to equidistant bus cycleEncoderNetwork settings in ms:Equidistant bus cycle activatedEquidistant DP cycle: 1.533Equidistance master cyclic component: 0.516Master applicationcycle [ms]:DP cycle [ms]: 1.625Factor1.625 = 1x 1.625=Factor13xIncrements/base time [ms]Increments/base time [ms]0.125Time T i [ms]:(Actual valueacquisition)Time T o [ms]:(Setpoint transfer)0.1250.750==Factor1Factor6xxIncrements/base time [ms]0.125Increments/base time [ms]0.125AlignmentOKCancelHelpFig. 2-6Dialog: DP slave propertiesNoteIf there are different equidistant DP slave types (for example, different SIMO-DRIVE drives, <strong>ADI4</strong>, etc.) in an S7 project, you must first perform the following twosteps for each DP slave type:1. Synchronize drive to equidistant DP cycle2. AlignmentThen, continue setting the other parameters. Siemens AG, <strong>2003</strong>. All rights reserved<strong>ADI4</strong> – Analog Drive Interface for 4 Axes, <strong>02</strong>.<strong>2003</strong> Edition2-51