Parameterization2.9.8 AdjustmentThe adjustment transfers all values for the current <strong>ADI4</strong> DP slave displayed in the“Cycle clock synchronization” tab to all other <strong>ADI4</strong> DP slaves in the configuration.Dialog: EndDialog box: “DP Slave Properties”Tab: “Cycle clock synchronization”Button: AdjustOKSee Figure 2-10, Page 2-59.NoteIf an S7 project includes different equidistant DP slave types, such as differentSIMODRIVE drives, <strong>ADI4</strong>, etc., the following parameter settings must be made asdescribed above for each DP slave type, and an adjustment must be performed: Equidistant DP cycle T DPMaster application cycle T MAPCActual value acquisition T iSetpoint transfer T oThe adjustment only transfers the values displayed in the “Cycle clock synchronization”tab to DP slaves of the same type.After the adjustment is performed, the parameterization of all <strong>ADI4</strong> DP slaves withrespect to the DP communication is completed.2-58 Siemens AG, <strong>2003</strong>. All rights reserved<strong>ADI4</strong> – Analog Drive Interface for 4 Axes, <strong>02</strong>.<strong>2003</strong> Edition