Input Properties<br />

• trigger: When trig mode is set to all, triggers starts ramping the envelope<br />

from the beginning. When trig mode is set to ind/one, starts ramping the next<br />

segment of the envelope. (See trig mode) for more info.<br />

• segments: Specifies how many segments are in the envelope, from 1 to 99.<br />

This number determines how many pairs of rate and level input properties will<br />

be found along the left edge of the actor.<br />

• trig mode: specifies what will happen when a trigger is received at the trigger<br />

input, and when triggers will be sent out of the end trigger output.<br />

When this property is set to all and a trigger is received, the envelope starts<br />

ramping from the first segment each time a trigger is received and continues<br />

until the last segment is complete. At the completion of the last segment, a<br />

trigger is sent out of the end trigger output.<br />

When set to ind/one or ind/end, each trigger ramps the next segment of the<br />

envelope. If no segments have been triggered yet, or if all the segments have<br />

been triggered, then the ramping begins at the first segment. The difference<br />

between ind/one and ind/end has to do with the end trigger output. When set<br />

to ind/one, a trigger is sent out of the end trigger output at the end of each<br />

segment. When set to ind/end the end trigger output is triggered at the<br />

completion of the last segment.<br />

• value 0: the starting value for the first segment.<br />

• rate 1, rate 2, etc.: Determines the number of seconds that it takes to get from<br />

the previous level to the next level. E.g., rate 1 specifies how long it takes to<br />

get from level 0 to level 1.<br />

• value 1, value 2, etc.: The value at that point in the envelope. Together with<br />

the rate between them, a pair of subsequent levels (e.g. level 1, rate 2, level 2)<br />

defines a ramp segment.<br />

Output Properties<br />

• output: The value of the envelope as it moves through the segments.<br />

• end trigger: sends a trigger at the end of the entire envelope, or at the end of a<br />

segment depending on the setting of the trig mode property. (See trig mode<br />

above for more information.)<br />