EiUK USER MANUAL RASI 700<br />

14.5 Leak proof test<br />

With the leak proof test the system is checked by the device (incl. the<br />

condensate separator) up to the probe spike on undensity. The internal<br />

gas pump generates in addition a subpressure which is measured over the<br />

built-in draft sensor and is observed for a period of 10 seconds. Based<br />

on the decrease of pressure the leakness of the system will be determined.<br />

Operation:<br />

• The leak proof test cap # 61382 (for probe tubes Ø 8 mm) must be<br />

put on on the probe spike.<br />

ATTENTION:<br />

The probe spike before the density test clean!<br />

(With depositions on the tube the cap does not<br />

seal.)<br />

• Launch under “extras” the leak proof test on which the following<br />

window will pop up:<br />

OK<br />

…<br />

If of the leak proof test is not passed the probe must be checked including<br />

the hosing as well as the condensate separator.<br />