EiUK USER MANUAL RASI 700<br />

15 TECHNICAL SPECIFICATIONS<br />

Measured values RASI 700<br />

Electro chemical sensors<br />

O 2<br />

Measurement range<br />

Accuracy<br />

Reaction time T90*<br />

0 - 21,0 Vol-%<br />

± 0,2 Vol-% absolute<br />

< 20 sec<br />

CO (H 2 comp.) (optional #<br />

63132)<br />

Measurement range<br />

Accuracy<br />

Reaction time T90*<br />

CO low (optional # 63133)<br />

Measurement range<br />

Accuracy<br />

CO high (optional #<br />

63057)<br />

Measurement range<br />

Accuracy<br />

Reaction time T90*<br />

CO very high (optional #<br />

63134)<br />

Measurement range<br />

Accuracy<br />

Reaction time T90*<br />

NO (optional # 63058)<br />

Measurement range<br />

Accuracy<br />

Reaction time T90*<br />

NO low (optional # 63135)<br />

Measurement range<br />

Accuracy<br />

NO2 (optional # 63059)<br />

Measurement range<br />

Accuracy<br />

Reaction time T90*<br />

0 - 4.000 ppm, overload up to 10.000 ppm<br />

± 10 ppm or** 5 % of the measured value up to<br />

4.000 ppm<br />

or** 10 % of the measured value up to 10.000<br />

ppm<br />

< 40 sec<br />

0 - 300 ppm, with 0,1 ppm resolution<br />

± 2,0 ppm or ** 5 % reading<br />

0 - 4.000 ppm, overload up to 20.000 ppm<br />

± 100 ppm or** 5 % of the measured value up<br />

to 4.000 ppm<br />

or** 10 % of the measured value up to 20.000<br />

ppm<br />

< 40 sec<br />

0 – 4,0 %, overload up to 20.000 ppm<br />

± 0,02 or** 5 % of the measured value up to<br />

4,00 %<br />

or** 10 % of the measured value up to 20.000<br />

ppm<br />

< 40 sec<br />

0 - 1.000 ppm, overload up to 5.000 ppm<br />

± 5 ppm or** 5 % of the measured value up to<br />

1.000 ppm<br />

or** 10 % of the measured value up to 5.000<br />

ppm<br />

≤ 30 sec<br />

0 - 300 ppm, with 0,1 ppm resolution<br />

± 2,0 ppm or ** 5 % reading<br />

0 - 200 ppm, overload up to 1.000 ppm<br />

± 5 ppm or** 5 % of the measured value up to<br />

200 ppm<br />

or** 10 % of the measured value up to 1.000<br />

ppm<br />

≤ 60 sec<br />

62