PART 7 MEMBERS SUBJECT TO COMBINED ACTIONS<br />

D7.1 SCOPE<br />

This part of the Tables contains the interaction formulae which must be used to design members subject<br />

to combined actions in accordance with Section 8 of AS 4100.The table below provides the location of<br />

design capacities and reference points within this publication for checking interaction effects on member<br />

capacities.<br />

Design<br />

Capacity Description Reference<br />

Nomx Elastic flexural buckling load of a member, about the principal x- axis Tables 7.3.2-1 to D7.3.2-4<br />

Nomy Elastic flexural buckling load of a member, about the principal y- axis Tables 7.3.2-1 to D7.3.2-4<br />

φNc Nominal member capacity in compression Tables D5.2-1(A) to D5.2-4<br />

φNs Design section capacity in axial compression Tables D3.1-1 to D3.1-4<br />

φNt Design section capacity in axial tension Tables D3.1-1 to D3.1-4<br />

φMs Design section moment capacity (SHS) Tables D3.1-1 to D3.1-4<br />

φMsx, φMsy φMs about x- and y- axes (RHS) Tables D3.1-1 & D3.1-3<br />

φMrx (comp) φMsx reduced by axial compression force (RHS) Section D7.4.1.1<br />

φMrx (tens) φMsx reduced by axial tension force (RHS) Section D7.5.1.1<br />

φMry φMsy reduced by axial force (RHS) Section D7.4.2.1 & D7.5.2.1<br />

φMr (comp) φMs about a principal axis reduced by axial compression force Section D7.4.1.1<br />

φMr (tens) φMs about a principal axis reduced by axial tension force Section D7.5.1.1<br />

φMb Design moment capacity (RHS) Tables D4.1-1 to D4.1-2<br />

φVv Design shear capacity of a web (SHS) Table D3.1-2 & D3.1-4<br />

φVvx φVv for bending about x- axis (RHS) Table D3.1-1 & D3.1-3<br />

φVvy φVv for bending about y- axis (RHS) Table D3.1-1 & D3.1-3<br />

φMz Design torsional section moment capacity Tables D3.1-1 to D3.1-4<br />

D7.2 METHOD<br />

Section D7.3 describes the use and determination of moment amplification factors and the determination<br />

of the elastic buckling load for braced or sway members. The elastic buckling load required for combined<br />

bending and axial compression when the moment is amplified by the moment amplification factors δ b and<br />

δ s .<br />

Sections D7.4 and D7.5 give the interaction formulae for combined bending and axial compression and<br />

combined bending and axial tension respectively. Each section describes the method for uniaxial bending<br />

about the major principal x-axis, for uniaxial bending about the minor principal y-axis, and for biaxial<br />

bending. Section D7.6 gives the interaction formulae for biaxial bending without axial forces. In every<br />

case both the section capacity and the member capacity must be checked.<br />

D7.3 MOMENT AMPLIFICATION<br />

For a member subjected to combined bending and axial compression force, irrespective of whether that<br />

member is an isolated statically determinate member or part of a statically indeterminate frame the bending<br />

moments will be amplified by the presence of axial compression force. Such amplification can be accounted<br />

for by a variety of means and these are now considered in relation to braced and sway members.<br />

Braced Member - the member is braced such that its ends cannot move relative to one another.<br />

If a first order elastic analysis is conducted then δ b (Clause 4.4.2.2 of AS 4100) must be used to amplify<br />

the design action effects between the ends of the member. However, when the moment amplification<br />

factor is greater than 1.4, a second order elastic analysis must be carried out (see Appendix E of AS<br />