TABLE D1.3-1(A)<br />

FIRE ENGINEERING DESIGN<br />

EXPOSED SURFACE AREA TO MASS RATIO (m 2 /t)<br />

DuraGal RECTANGULAR HOLLOW SECTIONS: GRADE C450L0<br />

Standard Thickness<br />

about x-axis<br />

1 = TOTAL PERIMETER, PROFILE-PROTECTED<br />

2 = TOTAL PERIMETER, BOX-PROTECTED, NO GAP<br />

3 = TOTAL PERIMETER, BOX-PROTECTED, 25mm GAP<br />

4 = TOP FLANGE EXCLUDED, PROFILE-PROTECTED<br />

5 = TOP FLANGE EXCLUDED, BOX-PROTECTED, NO GAP<br />

6 = TOP FLANGE EXCLUDED, BOX PROTECTED, 25mm GAP<br />

Designation<br />

Mass<br />

d b t per m<br />

1 2 3 4 5 6<br />

mm mm mm kg/m<br />

150 x 50 x 6.0 RHS 16.7 22.4 23.9 35.8 21.2 20.9 26.9<br />

5.0 RHS 14.2 26.6 28.1 42.1 24.8 24.6 31.6<br />

4.0 RHS 11.6 32.9 34.4 51.6 30.3 30.1 38.7<br />

3.0 RHS 8.96 43.5 44.7 67.0 39.3 39.1 50.2<br />

2.5 RHS 7.53 52.0 53.1 79.7 46.7 46.5 59.8<br />

2.0 RHS 6.07 64.7 65.9 98.8 57.8 57.6 74.1<br />

125 x 75 x 6.0 RHS 16.7 22.4 23.9 35.8 19.7 19.4 25.4<br />

5.0 RHS 14.2 26.6 28.1 42.1 23.1 22.8 29.8<br />

4.0 RHS 11.6 32.9 34.4 51.6 28.2 28.0 36.6<br />

3.0 RHS 8.96 43.5 44.7 67.0 36.5 36.3 47.5<br />

2.5 RHS 7.53 52.0 53.1 79.7 43.4 43.2 56.5<br />

2.0 RHS 6.07 64.7 65.9 98.8 53.7 53.5 70.0<br />

100 x 50 x 6.0 RHS 12.0 22.8 24.9 41.6 21.1 20.8 29.1<br />

5.0 RHS 10.3 27.0 29.1 48.5 24.6 24.2 33.9<br />

4.0 RHS 8.49 33.3 35.4 58.9 29.8 29.5 41.2<br />

3.5 RHS 7.53 37.9 39.9 66.4 33.5 33.2 46.5<br />

3.0 RHS 6.60 43.9 45.5 75.8 38.1 37.9 53.0<br />

2.5 RHS 5.56 52.4 53.9 89.8 45.2 44.9 62.9<br />

2.0 RHS 4.50 65.1 66.6 111 55.8 55.5 77.7<br />

1.6 RHS 3.64 81.0 82.5 138 69.0 68.8 96.3<br />

75 x 50 x 6.0 RHS 9.67 23.2 25.8 46.5 21.1 20.7 31.0<br />

5.0 RHS 8.35 27.4 29.9 53.9 24.4 23.9 35.9<br />

4.0 RHS 6.92 33.7 36.1 65.1 29.3 28.9 43.4<br />

3 0 RHS 5.42 44.2 46.1 83.0 37.2 36.9 55.3<br />

2.5 RHS 4.58 52.7 54.5 98.2 43.9 43.6 65.4<br />

2.0 RHS 3.72 65.4 67.2 121 54.1 53.8 80.7<br />

1.6 RHS 3.01 81.3 83.1 150 66.8 66.5 99.7<br />

75 x 25 x 2.5 RHS 3.60 53.1 55.5 111 49.0 48.6 76.3<br />

2.0 RHS 2.93 65.8 68.2 136 60.0 59.7 93.7<br />

1.6 RHS 2.38 81.7 84.0 168 73.9 73.5 116<br />

65 x 35 x 4.0 RHS 5.35 34.2 37.4 74.8 31.4 30.9 49.6<br />

3.0 RHS 4.25 44.7 47.1 94.2 39.3 38.9 62.4<br />

2.5 RHS 3.60 53.1 55.5 111 46.2 45.8 73.6<br />

2.0 RHS 2.93 65.8 68.2 136 56.6 56.2 90.3<br />

50 x 25 x 3.0 RHS 3.07 45.5 48.9 114 41.3 40.7 73.3<br />

2.5 RHS 2.62 54.0 57.2 134 48.2 47.7 85.8<br />

2.0 RHS 2.15 66.6 69.8 163 58.7 58.2 105<br />

1.6 RHS 1.75 82.5 85.6 200 71.9 71.4 128<br />

50 x 20 x 3.0 RHS 2.83 45.8 49.4 120 43.0 42.4 77.7<br />

2.5 RHS 2.42 54.2 57.7 140 50.1 49.5 90.7<br />

2.0 RHS 1.99 66.8 70.3 171 60.8 60.3 110<br />

1.6 RHS 1.63 82.7 86.1 209 74.3 73.8 135<br />

See page D1-7 for details of the cases of fire exposure considered.<br />

DCTDHS/06<br />

DuraGal DESIGN CAPACITY TABLES<br />

MARCH 2002 for STRUCTURAL STEEL HOLLOW SECTIONS D1-17