3-phase TEFV induction motors ATEX GAS - Zones 1 & 2
3-phase TEFV induction motors ATEX GAS - Zones 1 & 2
3-phase TEFV induction motors ATEX GAS - Zones 1 & 2
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
IEC symbol<br />
n x MS<br />
HJ<br />
α = 45°<br />
I<br />
M<br />
AC<br />
II<br />
<strong>TEFV</strong> <strong>induction</strong> <strong>motors</strong><br />
FLSD flameproof - Zone 1<br />
Dimensions<br />
E2.6 - Face mounted IM B14 (IM 3601)<br />
Ø AC<br />
LB<br />
J LJ<br />
Faceplate dimensions Main dimensions<br />
T<br />
Dimensions in millimetres<br />
M N P T n α° Thread x length Type AC LB HJ LJ J I II*<br />
FT 100 100 80 120 3 4 45 M6 x 13 FLSD 80 L 167 258 203 26 142 71 77<br />
FT 115 115 95 140 3 4 45 M8 x 13 FLSD 90 S 184 297 216 32 142 71 77<br />
FT 115 115 95 140 3 4 45 M8 x 13 FLSD 90 L 184 297 216 32 142 71 77<br />
FT 130 130 110 160 3.5 4 45 M8 x 13 FLSD 100 L 195 345 216 32 142 71 77<br />
FT 130 130 110 160 3.5 4 45 M8 x 13 FLSD 112 M 220 346 225 34 142 71 77<br />
FT 215 215 180 250 4 4 45 M12 x 20 FLSD 132 S 264 462 239 56 142 71 77<br />
FT 215 215 180 250 4 4 45 M12 x 20 FLSD 132 M 264 462 239 56 142 71 77<br />
IEC symbol<br />
Faceplate dimensions<br />
M N P T n α° Thread x length<br />
FT 165 165 130 200 3.5 4 45 M10 x 20<br />
* Dimensions not including cable gland<br />
j6<br />
N<br />
P<br />