4<br />
poles<br />
1500 min-1<br />
Type<br />
<strong>TEFV</strong> <strong>induction</strong> <strong>motors</strong> - Aluminium frame<br />
LSE increased safety - Zone 1<br />
Selection data<br />
Rated<br />
power<br />
Rated<br />
speed<br />
Rated<br />
torque<br />
G1.5 - 4 poles - 1500 min -1<br />
Ex e II T4<br />
Rated<br />
current<br />
MAINS SUPPLY D 230 / Υ 400 V or D 400 V 50 Hz<br />
Power<br />
factor<br />
Efficiency<br />
IEC 60034-2; 1996<br />
Starting<br />
current/<br />
Rated<br />
current<br />
Starting<br />
torque/<br />
Rated<br />
torque<br />
IP 55<br />
Cl. F - DT 80K<br />
400 V ± 10%<br />
Maximum<br />
torque/<br />
Rated<br />
torque<br />
Locked<br />
rotor<br />
time<br />
Moment<br />
of inertia<br />
Weight Noise<br />
P N N N M N I N (400V) Cos φ η Id/In Md/Mn M M /Mn t E J IM B3 LP<br />
kW min -1 N.m A % s kg.m 2 kg db(A)<br />
LSE 80 L 0.55 1425 3.75 1.4 0.76 75 5.2 1.9 2.2 9 0.0024 10.9 47<br />
LSE 90 L 0.75 1450 5 1.7 0.81 80.5 6.5 2.0 2.7 6 0.0032 13.5 48<br />
LSE 90 L 1.1 1447 7.5 2.5 0.78 82.1 6.7 1.8 2.3 5.5 0.0037 15.2 48<br />
LSE 100 L 1.5 1442 10 3.3 0.8 82.8 6.3 1.8 2.2 6 0.0064 25.5 48<br />
LSE 100 LG 2.2 1466 15 4.4 0.84 87.3 7.3 1.8 2.2 5 0.0109 30.5 48<br />
LSE 112 MU 3 1464 20 5.9 0.85 87.8 7.6 2.0 2.2 5 0.014 36.5 49<br />
LSE 132 SM 4 1465 27.5 7.4 0.89 88 7.7 1.8 2.6 5 0.019 54.7 62<br />
LSE 132 SM 5.5 1466 37.5 10.4 0.87 89.1 8.1 2.0 2.7 5 0.023 59.9 62<br />
LSE 132 MU 7.5 1461 50 13.8 0.88 89.2 7.4 1.6 2.3 5 0.0306 65.5 62