11.12.2012 Views

3-phase TEFV induction motors ATEX GAS - Zones 1 & 2

3-phase TEFV induction motors ATEX GAS - Zones 1 & 2

3-phase TEFV induction motors ATEX GAS - Zones 1 & 2

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

78<br />

4<br />

poles<br />

1500 min-1<br />

Type<br />

<strong>TEFV</strong> <strong>induction</strong> <strong>motors</strong> - Aluminium frame<br />

LSE increased safety - Zone 1<br />

Selection data<br />

Rated<br />

power<br />

Rated<br />

speed<br />

Rated<br />

torque<br />

G1.5 - 4 poles - 1500 min -1<br />

Ex e II T4<br />

Rated<br />

current<br />

MAINS SUPPLY D 230 / Υ 400 V or D 400 V 50 Hz<br />

Power<br />

factor<br />

Efficiency<br />

IEC 60034-2; 1996<br />

Starting<br />

current/<br />

Rated<br />

current<br />

Starting<br />

torque/<br />

Rated<br />

torque<br />

IP 55<br />

Cl. F - DT 80K<br />

400 V ± 10%<br />

Maximum<br />

torque/<br />

Rated<br />

torque<br />

Locked<br />

rotor<br />

time<br />

Moment<br />

of inertia<br />

Weight Noise<br />

P N N N M N I N (400V) Cos φ η Id/In Md/Mn M M /Mn t E J IM B3 LP<br />

kW min -1 N.m A % s kg.m 2 kg db(A)<br />

LSE 80 L 0.55 1425 3.75 1.4 0.76 75 5.2 1.9 2.2 9 0.0024 10.9 47<br />

LSE 90 L 0.75 1450 5 1.7 0.81 80.5 6.5 2.0 2.7 6 0.0032 13.5 48<br />

LSE 90 L 1.1 1447 7.5 2.5 0.78 82.1 6.7 1.8 2.3 5.5 0.0037 15.2 48<br />

LSE 100 L 1.5 1442 10 3.3 0.8 82.8 6.3 1.8 2.2 6 0.0064 25.5 48<br />

LSE 100 LG 2.2 1466 15 4.4 0.84 87.3 7.3 1.8 2.2 5 0.0109 30.5 48<br />

LSE 112 MU 3 1464 20 5.9 0.85 87.8 7.6 2.0 2.2 5 0.014 36.5 49<br />

LSE 132 SM 4 1465 27.5 7.4 0.89 88 7.7 1.8 2.6 5 0.019 54.7 62<br />

LSE 132 SM 5.5 1466 37.5 10.4 0.87 89.1 8.1 2.0 2.7 5 0.023 59.9 62<br />

LSE 132 MU 7.5 1461 50 13.8 0.88 89.2 7.4 1.6 2.3 5 0.0306 65.5 62