3-phase TEFV induction motors ATEX GAS - Zones 1 & 2
3-phase TEFV induction motors ATEX GAS - Zones 1 & 2
3-phase TEFV induction motors ATEX GAS - Zones 1 & 2
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
2<br />
poles<br />
3000 min-1<br />
Type<br />
<strong>TEFV</strong> <strong>induction</strong> <strong>motors</strong> - Aluminium frame<br />
LSE increased safety - Zone 1<br />
Selection data<br />
Rated<br />
power<br />
Rated<br />
speed<br />
Rated<br />
torque<br />
G1.4 - 2 poles - 3000 min -1<br />
Ex e II T4<br />
Rated<br />
current<br />
MAINS SUPPLY D 230 / Υ 400 V or D 400 V 50 Hz<br />
Power<br />
factor<br />
Efficiency<br />
IEC 60034-2; 1996<br />
Starting<br />
current/<br />
Rated<br />
current<br />
Starting<br />
torque/<br />
Rated<br />
torque<br />
IP 55<br />
Cl. F - DT 80K<br />
400 V ± 10%<br />
Maximum<br />
torque/<br />
Rated<br />
torque<br />
Locked<br />
rotor<br />
time<br />
Moment<br />
of inertia<br />
Weight Noise<br />
P N N N M N I N (400V) Cos φ η Id/In Md/Mn M M /Mn t E J IM B3 LP<br />
kW min -1 N.m A % s kg.m 2 kg db(A)<br />
LSE 80 L 0.75 2879 2.5 1.5 0.84 83.2 7.3 2.5 3.0 5 0.0011 11.3 61<br />
LSE 90 L 1.1 2865 3.7 2.1 0.91 83.9 7.6 2.1 2.7 5 0.0021 16 64<br />
LSE 90 L 1.5 2865 5 2.9 0.92 84 8.6 3.2 3.1 5 0.0021 16 64<br />
LSE 100 L 2.2 2850 7.4 4.2 0.93 84.5 8.8 2.8 3.4 5 0.0029 24 66<br />
LSE 112 MU 3 2924 10.1 5.3 0.94 86.7 9.1 2.7 3.4 5 0.0088 39 66<br />
LES 132 SM 4 2944 13.5 7.5 0.87 88.4 9.7 2.1 3.2 5 0.016 49 72<br />
LSE 132 SM 5.5 2953 18.6 9.7 0.92 89.5 8.9 1.7 2.7 5 0.018 54 72<br />
LSE 160 MP 7.5 2933 25.4 12.9 0.94 89.9 5.9 1.4 2.2 7.3 0.023 68 72<br />
77