H2.10.2 - LSE and LSN <strong>motors</strong><br />

3-<strong>phase</strong> <strong>TEFV</strong> <strong>induction</strong> <strong>motors</strong><br />

<strong>ATEX</strong> <strong>GAS</strong> - <strong>Zones</strong> 1 & 2<br />

Optional features<br />

H2 - Mechanical options<br />

H2.10.1 - FLSD flameproof <strong>motors</strong><br />

Some FLSD <strong>motors</strong> can be fitted with faceplates with different dimensions from those specified<br />

by the IEC standard. The table below indicates the optional flanges available by motor type:<br />

Flange type<br />

Motor type FF 130<br />

(FF) Flange mounted (FT) Face mounted<br />

FF 165<br />

FF 215<br />

FF 265<br />

FT 100<br />

FLSD 80 m l l<br />

FLSD 90 ¬ l l<br />

FLSD 100 ¬ l l<br />

FLSD 112 m l l<br />

FLSD 132 l m l<br />

l standard m modified bearing location ¬ adaptable without modification<br />

The LSE and LSN ranges of <strong>motors</strong> with aluminium frame can be fitted with numerous flanges and faceplates with different dimensions from those specified by the IEC<br />

standard. The table below indicates the optional flanges available by motor type:<br />

Flange type<br />

Motor type FF 100<br />

FF 115<br />

FF 130<br />

FF 165<br />

(FF) Flange mounted (FT) Face mounted<br />

FF 215<br />

FF 265<br />

FF 300<br />

FF 350<br />

LSE/LSN 56 l l ¬ ¬ ¬<br />

LSE/LSN 63 m l ¬ ¬ l ¬ ¬ ¬<br />

LSE/LSN 71 m m l m ¬ ¬ l ¬ ¬ ¬<br />

LSE/LSN 80 m m l ¬ ¬ l ¬ ¬ ¬<br />

LSE/LSN 90 ¬ ¬ l ¬ ¬ l ¬<br />

LSE/LSN 90 (Foot) m m m m ¬ l ¬ m<br />

LSE/LSN 100 m m m l ¬ l ¬ ¬<br />

LSE/LSN 112 M m m m l ¬ l ¬ ¬<br />

LSE/LSN 112 MG m m l ¬ ¬ l ¬ ¬<br />

LSE/LSN 132 S m ¬ l ¬ ¬ l ¬<br />

LSE/LSN 132 SM/M/MU m m l m ¬ l ¬<br />

LSE/LSN 160 MP/L/LR ¬ ¬ l ¬ l ¬<br />

LSE/LSN 180 l ¬<br />

LSE/LSN 200 ¬ l ¬<br />

LSE/LSN 225 l ¬<br />

LSE/LSN 250 ¬ l<br />

LSE/LSN 280 l ¬<br />

LSE/LSN 315 ¬ l<br />

l standard m modified bearing location ¬ adaptable without modification : non-standard<br />

FF 400<br />

FF 500<br />

FF 600<br />

FT 65<br />

FT 75<br />

FT 85<br />

FT 100<br />

FT 115<br />

FT 115<br />

FT 130<br />

FT 130<br />

FT 165<br />

FT 165<br />

FT 215<br />

FT 215<br />

FT 265<br />

95

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!