3-phase TEFV induction motors ATEX GAS - Zones 1 & 2
3-phase TEFV induction motors ATEX GAS - Zones 1 & 2
3-phase TEFV induction motors ATEX GAS - Zones 1 & 2
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
58<br />
6<br />
poles<br />
1000 min-1<br />
Type<br />
Rated<br />
power<br />
<strong>TEFV</strong> <strong>induction</strong> <strong>motors</strong> - Cast iron frame<br />
FLSE increased safety - Zone 1<br />
Selection data<br />
Rated<br />
speed<br />
Rated<br />
torque<br />
F1.3 - 6 poles - 1000 min -1<br />
Ex e II T3<br />
Rated<br />
current<br />
MAINS SUPPLY D 230 / Υ 400 V or D 400 V 50 Hz<br />
Power<br />
factor<br />
Efficiency<br />
IEC 60034-2; 1996<br />
Starting<br />
current/<br />
Rated<br />
current<br />
Starting<br />
torque/<br />
Rated<br />
torque<br />
IP 55<br />
Cl. F - DT 80K<br />
400 V ± 10%<br />
Maximum<br />
torque/<br />
Rated<br />
torque<br />
Locked<br />
rotor<br />
time<br />
Moment<br />
of inertia<br />
Weight Noise<br />
P N N N M N I N (400V) Cos φ η Id/In Md/Mn M M /Mn t E J IM B3 LP<br />
kW min -1 N.m A % s kg.m 2 kg db(A)<br />
FLSE 80 L 0.37 948 3.7 1.2 0.68 65.3 3.7 1.6 2.0 12 0.0028 16 40<br />
FLSE 80 L 0.55 955 5.5 1.8 0.64 68.6 4.5 2.1 2.4 8.4 0.0036 18 40<br />
FLSE 90 L 0.75 935 7.5 2.2 0.67 75 4.6 2.6 2.6 10.5 0.0037 23 45<br />
FLSE 90 LU 1.1 915 11.5 2.9 0.79 72.8 5.6 2.8 2.9 9 0.0048 25 45<br />
FLSE 100 LK 1.5 947 15 3.8 0.71 80.4 5.0 2.2 7.0 8.5 0.0136 41 48<br />
FLSE 112 M 2.2 960 22.7 5.3 0.76 81 6.2 2.2 2.7 7.3 0.012 44 48<br />
FLSE 132 SM 3 963 30 7 0.74 84.6 4.3 1.2 1.6 6.9 0.023 68 55<br />
FLSE 132 M 4 966 40 9.1 0.74 85.9 4.6 1.3 1.6 7.1 0.0275 72 55<br />
FLSE 132 MU 5.5 963 55 12.3 0.75 86.4 4.7 1.4 1.6 7.1 0.0343 78 55