Chapter 4. Peripheral<br />

4.2 Recommended MCCB and Magnetic Contactor<br />

Model MCCB (LSIS) ELB (LSIS) MC (LSIS)<br />

001<strong>iE5</strong>-1 5A 5A GMC- 9 7A<br />

002<strong>iE5</strong>-1 10A 10A GMC-12 9A<br />

004<strong>iE5</strong>-1 15A 15A GMC-18 13A<br />

ABS33b<br />

EBS33b<br />

001<strong>iE5</strong>-2 3A 3A GMC- 9 7A<br />

002<strong>iE5</strong>-2 5A 5A GMC- 9 7A<br />

004<strong>iE5</strong>-2<br />

10A<br />

10A GMC-12 9A<br />

4.3 Recommended Reactors<br />

Model AC Input fuse AC reactor DC reactor<br />

001<strong>iE5</strong>-1 20A 4.2mH, 3.5A 10mH, 3A<br />

002<strong>iE5</strong>-1 20A 4.2mH, 3.5A 10mH, 3A<br />

004<strong>iE5</strong>-1 20A 5.1mH, 5.4A 7mH, 5A<br />

001<strong>iE5</strong>-2 20A 4.2mH, 3.5A 10mH, 3A<br />

002<strong>iE5</strong>-2 20A 4.2mH, 3.5A 10mH, 3A<br />

004<strong>iE5</strong>-2 20A 4.2mH, 3.5A 7mH, 5A<br />