Chapter 7. Function List<br />
• PG Group<br />
Display Name<br />
P72 Filtering time<br />
constant for Multifunction<br />
Input<br />
terminal<br />
P73 Analog output item<br />
select<br />
P74 Analog output level<br />
adjustment<br />
P75 Frequency detection<br />
level<br />
P76 Frequency detection<br />
bandwidth<br />
P77 Multi-function relay<br />
select<br />
Adj.<br />
Min/Max<br />
Factory<br />
Description<br />
during<br />
range<br />
defaults<br />
run<br />
Page<br />
1 ~ 20 If the value is set higher, the responsiveness of the 3 O -<br />
Input terminal is getting slower.<br />
0 ~ 3<br />
Output item<br />
Output to 10[V] 0 O 11-5<br />
0 Output freq. Max frequency<br />
1 Output current 150 %<br />
2 Output voltage 282 V<br />
3 Inverter DC link voltage DC 400V<br />
10 ~ 200 Based on 10V. 100 O<br />
[%]<br />
0 ~ 200 Used when P77 is set to 0-4.<br />
30.00 O 11-7<br />
[Hz] Cannot be set higher than P16.<br />
~<br />
10.00 O 11-9<br />
0 ~ 17 0 FDT-1<br />
17 O 11-7<br />
1 FDT-2<br />
2 FDT-3<br />
11-8<br />
3 FDT-4<br />
4 FDT-5<br />
11-9<br />
5 -<br />
6 Inverter Overload (IOLt)<br />
7 Motor stall (STALL)<br />
8 Over voltage trip (OVt)<br />
9 Low voltage trip (LVt)<br />
10 Inverter cooling pin Overheat (OHt)<br />
11 Command loss<br />
11-10<br />
12 During Run<br />
13 During Stop<br />
14 During constant run<br />
15 During speed searching<br />
16 Wait time for run signal input<br />
17 Fault output select<br />
7-12