Chapter 7. Function List<br />

• PG Group<br />

Display Name<br />

Adj.<br />

Min/Max<br />

Factory<br />

Description<br />

during<br />

range<br />

defaults<br />

run<br />

Page<br />

P31 Dwell 0.1 ~ 200 When run frequency is issued, motor starts to 5.00 X 10-5<br />

frequency [Hz] accelerate after dwell frequency is applied to the<br />

motor during dwell time(P32).<br />

It can be set within max frequency(P16) and start<br />

frequency(P18).<br />

P32 Dwell time 0~10 Sets the time for dwell operation. 0.0<br />

[sec]<br />

X<br />

P33 Operator’s 0 ~ 7 Sets fault detection items at operator’s discretion 0 O 12-2<br />

fault<br />

[bit]<br />

detection<br />

Func. Earth<br />

Input phase Output<br />

detection<br />

during<br />

detection<br />

(CoL)<br />

phase<br />

detection<br />

Set run(GCt)<br />

(Pot)<br />

bit2 bit1 bit0<br />

0 - - -<br />

1 <br />

2 <br />

3 <br />

4 <br />

5 <br />

6 <br />

7 <br />

P34 Power On 0 ~ 1 It is activated when drv is set to 1 or 2.<br />

0 X 9-7<br />

Start<br />

Selection<br />

Motor starts acceleration after AC power is applied<br />

while FX or RX terminal is ON.<br />

P35 Restart after 0 ~1 It is activated when drv is set to 1 or 2 (Run/Stop via 0 O 9-8<br />

fault reset<br />

Control terminal).<br />

selection<br />

Motor accelerates after the fault condition is reset<br />

while the FX or RX terminal is ON.<br />

7-6