Chapter 7. Function List<br />
• PG Group<br />
Display Name<br />
Adj.<br />
Min/Max<br />
Factory<br />
Description<br />
during<br />
range<br />
defaults<br />
run<br />
Page<br />
P31 Dwell 0.1 ~ 200 When run frequency is issued, motor starts to 5.00 X 10-5<br />
frequency [Hz] accelerate after dwell frequency is applied to the<br />
motor during dwell time(P32).<br />
It can be set within max frequency(P16) and start<br />
frequency(P18).<br />
P32 Dwell time 0~10 Sets the time for dwell operation. 0.0<br />
[sec]<br />
X<br />
P33 Operator’s 0 ~ 7 Sets fault detection items at operator’s discretion 0 O 12-2<br />
fault<br />
[bit]<br />
detection<br />
Func. Earth<br />
Input phase Output<br />
detection<br />
during<br />
detection<br />
(CoL)<br />
phase<br />
detection<br />
Set run(GCt)<br />
(Pot)<br />
bit2 bit1 bit0<br />
0 - - -<br />
1 <br />
2 <br />
3 <br />
4 <br />
5 <br />
6 <br />
7 <br />
P34 Power On 0 ~ 1 It is activated when drv is set to 1 or 2.<br />
0 X 9-7<br />
Start<br />
Selection<br />
Motor starts acceleration after AC power is applied<br />
while FX or RX terminal is ON.<br />
P35 Restart after 0 ~1 It is activated when drv is set to 1 or 2 (Run/Stop via 0 O 9-8<br />
fault reset<br />
Control terminal).<br />
selection<br />
Motor accelerates after the fault condition is reset<br />
while the FX or RX terminal is ON.<br />
7-6