<strong>MODBUS</strong>/<strong>TCP</strong> <strong>Fieldbus</strong> <strong>manual</strong> 4 Function codes<br />

Trip on relative position The ASCII of the command mnemonic is sent in revers order in the request PDU i.e.<br />

RT. The parameter string is written or read in normal sequence.<br />

Note the the only trip function available is trip on relative position. to re-enable the trip,<br />

use register 0x007D.<br />

4.3.2 Read manufacturer specifi c – 65 (0x41)<br />

MCode mnemonic TR (Trip on relative position)<br />

Mnemonic<br />

Hi word<br />

Lo word<br />

0x20 0x20<br />

0x52 0x54<br />

Parameter data length Up to 11 bytes<br />

ASCII = 6 5 0 0 0<br />

Hex 3D 36 35 30 30 30<br />

Request Length Value<br />

Function code 1 byte 0x41<br />

Mnemonic Hi word 2 bytes 0x2020 0x2020/2033*<br />

Mnemonic Lo word 2 bytes See section 4.3.1 for listing<br />

*For capture/trip I/O point.<br />

Response Length Value<br />

Function code 1 byte 0x41<br />

Byte count 2 bytes N* (quantity of characters returned)<br />

Response n bytes n=N or N+1<br />

Error Length Value<br />

Error code 1 byte 0xC1<br />

Exception 1 byte 01, 02, 03 or 04<br />

Example Example shows reading the setting of the trip on relative input (TR). The<br />

value reads as 0x35 31 32 30 30 30 or decimal 512000 steps.<br />

Request Response<br />

Function 0x41 Function 0x41<br />

Mnemonic Hi word<br />

Mnemonic Lo word<br />

0x00<br />

0x35<br />

0x00 0x31<br />

0x52<br />

0x54<br />

Response<br />

0x32<br />

0x30<br />

0x30<br />

0x30<br />

4-11