17.12.2012 Views

MODBUS/TCP Fieldbus manual - Koco Motion GmbH

MODBUS/TCP Fieldbus manual - Koco Motion GmbH

MODBUS/TCP Fieldbus manual - Koco Motion GmbH

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Revision R020111<br />

<strong>MODBUS</strong>/<strong>TCP</strong> <strong>Fieldbus</strong> <strong>manual</strong> 6 <strong>TCP</strong>/IP Confi guration Utility<br />

6.5.2 Using the Manual tab to read functions / data<br />

Manual<br />

&H1<br />

&H0<br />

&H6<br />

&H1<br />

&H3<br />

&H0<br />

&H57<br />

&H0<br />

&H2<br />

&H0<br />

The following illustration shows an example of reading a function, in this<br />

case the position resulting from the absolute move in the last section.<br />

Transaction ID<br />

Protocol<br />

Length (of following bytes)<br />

Unit ID<br />

Function Code<br />

PDU byte 0x01<br />

PDU byte 0x02<br />

PDU byte 0x03<br />

PDU byte 0x04<br />

PDU byte 0x05<br />

0x 03 00 57 00 02 00<br />

Read Position<br />

Function<br />

Code<br />

Address<br />

Hi byte<br />

Address<br />

Lo byte<br />

Qty of<br />

registers<br />

Hi byte<br />

PDU<br />

Qty of<br />

registers<br />

Lo byte<br />

Qty of<br />

data bytes<br />

following<br />

&H0<br />

&H0<br />

&H0<br />

&H0<br />

Receive<br />

Func. / Error Code<br />

Data:<br />

PDU byte 0x06<br />

PDU byte 0x07<br />

PDU byte 0x08<br />

PDU byte 0x09<br />

0x3<br />

TransID:0x01; Protocol:0x00; Length:0x07;<br />

Unit_ID:0x1; Function_Code:0x3; Data(01):0x4;<br />

Data(02):0xD0; Data(03):0x0; Data(04):0x0;<br />

Data(05):0x7<br />

Response contains the data value<br />

D0 00 07 07 D0 00 07<br />

Figure 6.7: Reading a function using the Manual tab<br />

Send<br />

= 0x07D00 or 512000 decimal<br />

6-7