Increased cutter tool life with the powRgrip ® System<br />

Influence of tool runout on tool life / Source: In-house testing<br />

3<br />

Surface finish [Ra]<br />

2.5<br />

2<br />

1.5<br />

1<br />

0.5<br />

Ra 1.6<br />

All tool shanks are clampable<br />

All kind of materials such as carbide or HSS as<br />

of cylindrical, WELDON or Whistle Notch can<br />

be clamped with powRgrip ® .<br />

16 32 48 64 80 96 112 128 144 160 176<br />

Cutting length [m] /<br />

tool life<br />

powRgrip ®<br />

<strong>REGO</strong>-<strong>FIX</strong> ER System with Hi-Q ® clamping nut<br />

Shrink-fit<br />

Hydro chuck<br />

Extensive collet range<br />

Tools with shank diameters from 0.2 to 25.4 mm<br />

(1“) can be clamped for milling, reaming, drilling<br />

and as well for turning applications.<br />

The possibilities of MQL, peripheral or internal<br />

cooling are given.<br />

Transferable torque of the powRgrip ® System<br />

Measured transferable torque per shank diameter / Source: In-house testing<br />

Transferable torque [Nm]<br />

1200<br />

1000<br />

800<br />

600<br />

400<br />

200<br />

<strong>REGO</strong>-<strong>FIX</strong> powRgrip ® PG 32<br />

5 10 15 20 25<br />

Tool shank diameter [mm]<br />

powRgrip ® PG 32<br />

Shrink-fit<br />

Wide range of toolholders<br />

powRgrip ® -toolholders are available for many<br />

spindle interfaces e.g. <strong>REGO</strong>-<strong>FIX</strong> CAPTO, BT, BT+,<br />

SK, SK+, HSK, CAT, CAT+ or cylindrical spindle<br />

interfaces. Discover our wide product range at<br />

www.rego-fix.com.<br />

Hydro chuck<br />

<strong>REGO</strong>-<strong>FIX</strong> ER 40<br />

Measurement of vibrations | powRgrip ®<br />

Amplitude indication of the <strong>REGO</strong>-<strong>FIX</strong> powRgrip ® toolholder<br />

Measurement of vibrations | Shrink-fit holder<br />

Amplitude indication of a standard shrink-fit holder<br />

Amplitude [µm]<br />

120<br />

80<br />

40<br />

0<br />

-40<br />

-80<br />

-120<br />

-160<br />

0 0.002 0.004 0.06 0.08 0.1 0.12 0.14 0.16 0.18<br />

Amplitude [µm]<br />

120<br />

80<br />

40<br />

0<br />

-40<br />

-80<br />

-120<br />

-160<br />

0 0.002 0.004 0.06 0.08 0.1 0.12 0.14 0.16 0.18<br />

Time [s]<br />

Time [s]<br />

Test and comparison done by:<br />

Institute for production and high-performance laser technology<br />

Technical University Vienna<br />

Institut für Fertigungstechnik und Hochleistungslasertechnik<br />

Technische Universität Wien<br />

Expert advice<br />

Test powRgrip ® free of charge! Get more information at<br />

try.rego-fix.ch/toollife.<br />

Technical information<br />