02.02.2013 Views

Release Bulletin NP V10.4.1R02 - Comtech EF Data

Release Bulletin NP V10.4.1R02 - Comtech EF Data

Release Bulletin NP V10.4.1R02 - Comtech EF Data

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Example:<br />

Main Application<br />

- The DLS command displays STATE: LOOP for the local interface of the<br />

span:<br />

--[ LOCAL INTERFACE ]--------------------------------------------<br />

LINK# 0300 STATE: LOOP<br />

The Loopback condition discussed here has nothing to do with the Loopback<br />

Test (LT) command; rather, the Loopback parameter configured on a span.<br />

• Modified: On the SDM-9606 and SDM-9620 blades, the LED status of E1/T1<br />

ports is now updated every 10 seconds, rather than on a change of status only. For<br />

a 1:1 Redundancy application on the SDM-9620, LEDs on the redundant RTM<br />

are updated only when the unit state of the corresponding SDM-9620 blade is IN<br />

USE or DEACTIVATION IN PROGRESS, since in all other cases the redundant<br />

RTM is being used by the other SDM-9620 blade.<br />

• Resolved: The SDM-9620 no longer reboots in a loop after enabling the Log<br />

extended DSP errors/events parameter in the ELOG submenu of the Setup (SE)<br />

command.<br />

Legacy Protocols<br />

• Added: Two new extended port parameters can be used on the SDM-8400 to permit<br />

the transmission of DLE packets on ports configured with the COP protocol<br />

where the extended port parameter COPSPOOF must be set to NO, and DLE<br />

SYN ENABLE must be set to YES.<br />

This application requires the configuration of the DLE ETX and DLE ETB characters,<br />

which are sent without change over the port:<br />

• To set the DLE ETX character, enter the following at the console command<br />

prompt:<br />

EP PORT n ETXCAR XX<br />

where: XX is a hexadecimal value<br />

• To set the DLE ETB character, enter the following:<br />

EP PORT n ETBCAR XX<br />

where: XX is a hexadecimal value<br />

UNIT>EP PORT 3 ETBCAR 83<br />

EXTENDED PARAMETERS<br />

PORT 3> (ETBCAR) ETB character (hex).............83<br />

REMARK: To make this parameter effective, you have to turn off the<br />

port<br />

UNIT>EP PORT 3 ETXCAR 26<br />

EXTENDED PARAMETERS<br />

PORT 3> (ETXCAR) ETX character (hex).............26<br />

REMARK: To make this parameter effective, you have to turn off the<br />

port<br />

UNIT>EP<br />

Memotec Inc. 3-23