Release Bulletin NP V10.4.1R02 - Comtech EF Data
Release Bulletin NP V10.4.1R02 - Comtech EF Data
Release Bulletin NP V10.4.1R02 - Comtech EF Data
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Example:<br />
Main Application<br />
- The DLS command displays STATE: LOOP for the local interface of the<br />
span:<br />
--[ LOCAL INTERFACE ]--------------------------------------------<br />
LINK# 0300 STATE: LOOP<br />
The Loopback condition discussed here has nothing to do with the Loopback<br />
Test (LT) command; rather, the Loopback parameter configured on a span.<br />
• Modified: On the SDM-9606 and SDM-9620 blades, the LED status of E1/T1<br />
ports is now updated every 10 seconds, rather than on a change of status only. For<br />
a 1:1 Redundancy application on the SDM-9620, LEDs on the redundant RTM<br />
are updated only when the unit state of the corresponding SDM-9620 blade is IN<br />
USE or DEACTIVATION IN PROGRESS, since in all other cases the redundant<br />
RTM is being used by the other SDM-9620 blade.<br />
• Resolved: The SDM-9620 no longer reboots in a loop after enabling the Log<br />
extended DSP errors/events parameter in the ELOG submenu of the Setup (SE)<br />
command.<br />
Legacy Protocols<br />
• Added: Two new extended port parameters can be used on the SDM-8400 to permit<br />
the transmission of DLE packets on ports configured with the COP protocol<br />
where the extended port parameter COPSPOOF must be set to NO, and DLE<br />
SYN ENABLE must be set to YES.<br />
This application requires the configuration of the DLE ETX and DLE ETB characters,<br />
which are sent without change over the port:<br />
• To set the DLE ETX character, enter the following at the console command<br />
prompt:<br />
EP PORT n ETXCAR XX<br />
where: XX is a hexadecimal value<br />
• To set the DLE ETB character, enter the following:<br />
EP PORT n ETBCAR XX<br />
where: XX is a hexadecimal value<br />
UNIT>EP PORT 3 ETBCAR 83<br />
EXTENDED PARAMETERS<br />
PORT 3> (ETBCAR) ETB character (hex).............83<br />
REMARK: To make this parameter effective, you have to turn off the<br />
port<br />
UNIT>EP PORT 3 ETXCAR 26<br />
EXTENDED PARAMETERS<br />
PORT 3> (ETXCAR) ETX character (hex).............26<br />
REMARK: To make this parameter effective, you have to turn off the<br />
port<br />
UNIT>EP<br />
Memotec Inc. 3-23