4.2 CONNECTORS<br />
25-7-6 H J Blass, J Ehlbeck, M Schläger<br />
Characteristic strength of split-ring and shear plate connections<br />
Introduction<br />
During the last CEN TC 124 WG4 meeting in Trento, Italy, the convenor<br />
of WG4 presented a calculation model describing the load-bearing behaviour<br />
of split-ring and shear plate connections subjected to tensile forces<br />
parallel to the grain. Using this model existing test data are evaluated to<br />
determine characteristic strength values of split-ring and shear-plate connections.<br />
The result of the evaluation is compared to today's allowable<br />
loads of this type of mechanical timber connections.<br />
Calculation model<br />
The model used to describe the failure of split-ring and shear-plate connections<br />
assumes a shear block failure of the wood in front of the connector.<br />
The embedment stresses which in reality are unevenly distributed over<br />
the half circle of the split-ring are assumed to be uniformly distributed and<br />
acting parallel to the load direction. The embedment stresses are then<br />
transferred through shear stresses into the tension member (see Figure).<br />
For tension members the capacity of the bolt is neglected, since the bolt<br />
usually is placed in oversized holes and only just starts bearing when the<br />
split-ring connection fails.<br />
Conclusions<br />
In order to establish characteristic strength values of split-ring and shearplate<br />
connections old test data have been evaluated. The results of the<br />
evaluation show the suitability of a calculation model presented and discussed<br />
in Working Group 4 of CEN TC 124. This model assumes a block<br />
shear failure mode for joints loaded in tension. The influence of the bolt on<br />
the load-bearing capacity is neglected. Besides, the model provides consistent<br />
results also for joints loaded under an angle to the grain. For joints<br />
loaded in compression, the capacity of the bolt may additionally be taken<br />
into account.<br />
An influence of number of connector units per joint could not be found<br />
within the range covered by the test data. The same applies to the influence<br />
of the angle between load and grain direction. For angles up to 70°<br />
the 5-percentile value of the strength per connector was independent of the<br />
load-grain angle.<br />
25-7-7 H J Blass, J Ehlbeck, M Schläger<br />
Characteristic strength of tooth-plate connector joints<br />
Introduction<br />
The change of code formats in European timber codes from an allowable<br />
load format towards a partial safety coefficient format requires characteristic<br />
strength values of the material and of connections. For joints with pintype<br />
fasteners, the characteristic connection strength can be calculated using<br />
a solution based on the work of Johansen. Eurocode 5 provides those<br />
equations to calculate single and double-shear joints with nails, screws,<br />
dowels or bolts based on the joint geometry and the strength of the timber<br />
and the fastener. For other types of mechanical timber joints, characteristic<br />
strength values have still to be determined. The members of CEN TC 124<br />
WG4 have the task to establish characteristic strength values for connector<br />
joints. During the last CEN TC 124 WG4 meeting, a calculation model describing<br />
the load-bearing capacity of tooth-plate connections was presented.<br />
Using this model existing test data are evaluated to determine characteristic<br />
strength values of tooth-plate connections. The result of the evaluation<br />
is compared to today's allowable loads of this type of mechanical timber<br />
connections.<br />
Calculation model<br />
The model used to describe the load-carrying capacity of tooth-plate connections<br />
is based on the assumption of a load-sharing between tooth plate<br />
connector and bolt. The connection strength can therefore be described by:<br />
<strong>CIB</strong>-<strong>W18</strong> Timber Structures – A review of meeting 1-43 4 CONNECTIONS page 4.13