4.2 CONNECTORS<br />

25-7-6 H J Blass, J Ehlbeck, M Schläger<br />

Characteristic strength of split-ring and shear plate connections<br />

Introduction<br />

During the last CEN TC 124 WG4 meeting in Trento, Italy, the convenor<br />

of WG4 presented a calculation model describing the load-bearing behaviour<br />

of split-ring and shear plate connections subjected to tensile forces<br />

parallel to the grain. Using this model existing test data are evaluated to<br />

determine characteristic strength values of split-ring and shear-plate connections.<br />

The result of the evaluation is compared to today's allowable<br />

loads of this type of mechanical timber connections.<br />

Calculation model<br />

The model used to describe the failure of split-ring and shear-plate connections<br />

assumes a shear block failure of the wood in front of the connector.<br />

The embedment stresses which in reality are unevenly distributed over<br />

the half circle of the split-ring are assumed to be uniformly distributed and<br />

acting parallel to the load direction. The embedment stresses are then<br />

transferred through shear stresses into the tension member (see Figure).<br />

For tension members the capacity of the bolt is neglected, since the bolt<br />

usually is placed in oversized holes and only just starts bearing when the<br />

split-ring connection fails.<br />

Conclusions<br />

In order to establish characteristic strength values of split-ring and shearplate<br />

connections old test data have been evaluated. The results of the<br />

evaluation show the suitability of a calculation model presented and discussed<br />

in Working Group 4 of CEN TC 124. This model assumes a block<br />

shear failure mode for joints loaded in tension. The influence of the bolt on<br />

the load-bearing capacity is neglected. Besides, the model provides consistent<br />

results also for joints loaded under an angle to the grain. For joints<br />

loaded in compression, the capacity of the bolt may additionally be taken<br />

into account.<br />

An influence of number of connector units per joint could not be found<br />

within the range covered by the test data. The same applies to the influence<br />

of the angle between load and grain direction. For angles up to 70°<br />

the 5-percentile value of the strength per connector was independent of the<br />

load-grain angle.<br />

25-7-7 H J Blass, J Ehlbeck, M Schläger<br />

Characteristic strength of tooth-plate connector joints<br />

Introduction<br />

The change of code formats in European timber codes from an allowable<br />

load format towards a partial safety coefficient format requires characteristic<br />

strength values of the material and of connections. For joints with pintype<br />

fasteners, the characteristic connection strength can be calculated using<br />

a solution based on the work of Johansen. Eurocode 5 provides those<br />

equations to calculate single and double-shear joints with nails, screws,<br />

dowels or bolts based on the joint geometry and the strength of the timber<br />

and the fastener. For other types of mechanical timber joints, characteristic<br />

strength values have still to be determined. The members of CEN TC 124<br />

WG4 have the task to establish characteristic strength values for connector<br />

joints. During the last CEN TC 124 WG4 meeting, a calculation model describing<br />

the load-bearing capacity of tooth-plate connections was presented.<br />

Using this model existing test data are evaluated to determine characteristic<br />

strength values of tooth-plate connections. The result of the evaluation<br />

is compared to today's allowable loads of this type of mechanical timber<br />

connections.<br />

Calculation model<br />

The model used to describe the load-carrying capacity of tooth-plate connections<br />

is based on the assumption of a load-sharing between tooth plate<br />

connector and bolt. The connection strength can therefore be described by:<br />

<strong>CIB</strong>-<strong>W18</strong> Timber Structures – A review of meeting 1-43 4 CONNECTIONS page 4.13