for determination of the load-carrying capacity of joints with bulldog connectors,<br />
CEN TC 124/WG 4, April1993), the second a development of this<br />
formula based on work previously reported by the authors, and the third<br />
was a new, simplified formula.<br />
On average all three formulae predicted ultimate loads within 3 % of<br />
the test values. However, only the second and third formulae correctly assessed<br />
the effects on joint strength of timber density and member thickness.<br />
Since some design formulae which have been proposed involve separating<br />
the contribution of the bolt, it was decided to measure the strength of<br />
plain bolted joints made from timber of comparable density, and with bolts<br />
of the same two diameters that were used for the connectored joints. As<br />
mentioned in the Introduction, it was discovered that the ultimate loads on<br />
these bolted joints considerably exceeded the values predicted by the formulae<br />
in EC5, so two further sets of tests were conducted using bolts<br />
without nuts and washers, one with members of European redwood, the<br />
other with Southern pine in order to include a timber of higher density.<br />
Some of the bolts themselves were tested to determine their ultimate tensile<br />
strength.<br />
A further series of tests on toothed plates manufactured was conducted<br />
by Lee and Lord (TRADA report E/TR/21,1961). These plates were double-sided<br />
round toothed plates, similar to the other plates tested in 1993.<br />
On the basis of these tests, Formula (1) gives the most consistent and<br />
accurate results, but it must be noted that all the specimens tested had densities<br />
of around 500 kg/m 3 and were made with thin members of similar<br />
thickness; and, as previously noted, the formula as it stands does not adequately<br />
allow for variations in these parameters.<br />
1,5<br />
j. k 18 c b, k<br />
R � d � R<br />
(1)<br />
0,5 1,25 1,5<br />
j. k 0,0014 min�k<br />
c b, k<br />
R � t d � R<br />
(2)<br />
� �<br />
R � 0,0077 � d t � 40mm � R<br />
(3)<br />
j. k k c min b, k<br />
where<br />
R jk . is characteristic load-carrying capacity of one double-sided round<br />
toothed plate and bolt, in N<br />
R bk . is characteristic load-carrying capacity of the bolt per shear plane,<br />
calculated from Eurocode 5, in N<br />
is diameter of toothed plate, in mm<br />
dc<br />
t is minimum of outer member thickness and half the inner member<br />
thickness for 3-member joints or minimum member thickness for 3member<br />
joints, in mm<br />
� k is characteristic density, in kg/m 3 .<br />
All three formulae over-compensated for connector diameter according to<br />
these test results.<br />
Conclusions<br />
For real bolted joints made with nuts and washers, the bolt design formulae<br />
given in EC5 give good predictions of the yield loads but not of the absolute<br />
ultimate loads. The predicted loads appear to be about 70 % of the<br />
experimental values. It may be considered that design formulae for joints<br />
made with toothed plate connectors should in a similar way predict loadcarrying<br />
capacities which are less than the ultimate load-carrying capacity.<br />
25-7-10 A V Page, C J Mettem<br />
Characteristic strength of UK timber connectors<br />
Introduction<br />
In an official report to the meeting of CEN/TC 124 'WG4”, the members<br />
were asked<br />
(i) to describe a procedure for converting the allowable or working<br />
loads for timber connectored joints used in their country to characteristic<br />
load-carrying capacities<br />
(ii) to compare the values obtained in this way with corresponding values<br />
calculated from formulae proposed by E. Gehri:<br />
0,5<br />
1,5 � �k<br />
�<br />
c, k �15 c � b, k<br />
R<br />
where<br />
d � �<br />
�380 �<br />
R N<br />
dc is the diameter of the plate in mm<br />
� k is the characteristic timber density in kg/m 3<br />
R is the characteristic load-carrying capacity of the bolt in single<br />
<strong>CIB</strong>-<strong>W18</strong> Timber Structures – A review of meeting 1-43 4 CONNECTIONS page 4.15<br />
bk ,<br />
shear in N<br />
(iii) to make proposals for obtaining characteristic values for the connectors<br />
used in their country.