and considering observations during testing an optimized screw for load<br />

carrying joints with steel plates and screws under an angle of 45° can be<br />

derived. This screw includes a strengthened shaft of about 3d length under<br />

the head in order to minimize the curb effect of the steel plate’s edge.<br />

Then an additional free length of about 1,5d is added to reach the optimal<br />

embedment depth of 2d below the surface. Finally a thread length of about<br />

18-20d is applied to the screw. As lower bound 18d are suggested because<br />

the critical length that marks the transition of withdrawal failure to screw<br />

failure is at around 16d (depending on steel strength). If the effect of embedment<br />

is taken into account this length could even be reduced to 14 –<br />

16d.<br />

Figure 12: Optimized screw geometry for load carrying steel plate connections<br />

Based on the research concerning moisture content and feedback from<br />

practical use it is proposed to limit screws to applications inside the service<br />

class 1 and 2.<br />

42-7-2 H Krenn, G Schickhofer<br />

Joints with inclined Screws and Steel Plates as outer Members<br />

Introduction<br />

The load-carrying capacity of connections with dowel-type fasteners and<br />

steel plates as outer member of a single shear connection, determined on<br />

the basis of Johansen’s yield theory, is limited by the embedding strength<br />

of the timber member and the bending capacity of the fastener. The use of<br />

self-tapping screws with continuous threads with the screw axis perpendicular<br />

to the axis of the timber member is very inefficient because of the<br />

limited diameter and the relatively small bending capacity of the screws.<br />

The application of inclined screws that are arranged under an angle of<br />

45° between screw axis and member axis was presented by Bejtka & Blass<br />

as well as Kevarinmäki in 2002. They showed that the load-carrying capacity<br />

and the stiffness of timber-to-timber connections in these joints is a<br />

lot higher compared to common shear connections due to the high withdrawal<br />

capacity of the screws. Going one step further, the additional use of<br />

steel plates with special holes, incorporating the geometry of the screw<br />

head, leads to a further increase in load-carrying capacity and stiffness of<br />

this steel-to-timber connection. The ultimate load of these joints is then<br />

mainly limited by the withdrawal capacity and the tensile capacity of the<br />

screw as well as the friction between the steel plate and the timber member.<br />

These parameters are relatively well known, whereas the influence of<br />

the number of fasteners in such a connection is in question.<br />

This paper will present the results of tests of joints with inclined screws<br />

in glued laminated .timber and steel plates as outer members. Some aspects<br />

of the influence of the number of fasteners will be discussed and a<br />

proposal for design rules for single-shear joints with inclined screws will<br />

be presented. General considerations about the joint geometry and the<br />

screw arrangement will will conclude the publication.<br />

Conclusions<br />

The test results of this study showed that steel-to-timber joints with inclined<br />

self-tapping screws yield a very high load-carrying capacity and an<br />

even more impressive stiffness. A simple truss-model, incorporating the<br />

axial resistance of the screw and the friction in the interface between timber<br />

member and steel plate, is sufficient for reliable design of these joints<br />

(although the dowel effect could be observed to some extent). In the ultimate<br />

limit state, the effective number of screws shall be taken into account<br />

<strong>CIB</strong>-<strong>W18</strong> Timber Structures – A review of meeting 1-43 4 CONNECTIONS page 4.78