• Digital input - An alarm input for connecting devices that can toggle between an open and<br />

closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a<br />

signal is received the state changes and the input becomes active (shown under<br />

Events > Port Status).<br />

Function Pin Notes Specifications<br />

GND 1 Ground<br />

3.3 V DC<br />

Power<br />

Configurable<br />

(input or<br />

Output)<br />

2 Can be used to power auxiliary equipment.<br />

Note: This pin can only be used as power out.<br />

3-6 Digital input – Connect to GND to activate, or leave floating<br />

(unconnected) to deactivate.<br />

Digital output – Uses an open-drain NFET transistor with the<br />

source connected to GND. If used with an external relay, a<br />

diode must be connected in parallel with the load, for protection<br />

against voltage transients.<br />

Max. load = 250 mA<br />

Min. input = -40 V DC<br />

Max. input = +40 V DC<br />

Max. load = 100 mA<br />

Max. voltage = +40 V DC<br />

ENGLISH<br />

<strong>AXIS</strong> <strong>P5532</strong>/<strong>P5534</strong> Status indicators<br />

Color<br />

Unlit<br />

Amber<br />

Amber/red<br />

Red<br />

Green<br />

Indication<br />

Steady connection/normal operation<br />

Steady during system initiating and reset to factory default. Flashes during firmware upgrade.<br />

No network connection<br />

Firmware upgrade failure<br />

Steady for 10 sec. after successful restart<br />

Note:<br />

For more information on the <strong>AXIS</strong> <strong>P5532</strong>/<strong>P5534</strong> status indicators, please see the User’s<br />

Manual available from the <strong>AXIS</strong> Network Video Product CD supplied with this product or<br />

from the website at www.axis.com<br />

<strong>AXIS</strong> T8123 Status indicators<br />

LED Color Indication<br />

Port Unlit No camera connected<br />

Flashing<br />

Power overload or other input voltage error<br />

Green<br />

Camera connected, normal behavior<br />

AC input Steady green AC power connected