AXIS P5532/P5534 Installation Guide - Axis Communications
AXIS P5532/P5534 Installation Guide - Axis Communications
AXIS P5532/P5534 Installation Guide - Axis Communications
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
<strong>AXIS</strong> <strong>P5532</strong>/<strong>P5534</strong> <strong>Installation</strong> <strong>Guide</strong> Page 21<br />
• Digital input - An alarm input for connecting devices that can toggle between an open and<br />
closed circuit, for example: PIRs, door/window contacts, glass break detectors, etc. When a<br />
signal is received the state changes and the input becomes active (shown under<br />
Events > Port Status).<br />
Function Pin Notes Specifications<br />
GND 1 Ground<br />
3.3 V DC<br />
Power<br />
Configurable<br />
(input or<br />
Output)<br />
2 Can be used to power auxiliary equipment.<br />
Note: This pin can only be used as power out.<br />
3-6 Digital input – Connect to GND to activate, or leave floating<br />
(unconnected) to deactivate.<br />
Digital output – Uses an open-drain NFET transistor with the<br />
source connected to GND. If used with an external relay, a<br />
diode must be connected in parallel with the load, for protection<br />
against voltage transients.<br />
Max. load = 250 mA<br />
Min. input = -40 V DC<br />
Max. input = +40 V DC<br />
Max. load = 100 mA<br />
Max. voltage = +40 V DC<br />
ENGLISH<br />
<strong>AXIS</strong> <strong>P5532</strong>/<strong>P5534</strong> Status indicators<br />
Color<br />
Unlit<br />
Amber<br />
Amber/red<br />
Red<br />
Green<br />
Indication<br />
Steady connection/normal operation<br />
Steady during system initiating and reset to factory default. Flashes during firmware upgrade.<br />
No network connection<br />
Firmware upgrade failure<br />
Steady for 10 sec. after successful restart<br />
Note:<br />
For more information on the <strong>AXIS</strong> <strong>P5532</strong>/<strong>P5534</strong> status indicators, please see the User’s<br />
Manual available from the <strong>AXIS</strong> Network Video Product CD supplied with this product or<br />
from the website at www.axis.com<br />
<strong>AXIS</strong> T8123 Status indicators<br />
LED Color Indication<br />
Port Unlit No camera connected<br />
Flashing<br />
Power overload or other input voltage error<br />
Green<br />
Camera connected, normal behavior<br />
AC input Steady green AC power connected