You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
GB<strong>Finish</strong> <strong>270</strong> / <strong>250</strong>DesCription of unitBefore start with the backfitting, pull of mainplug of socket, disassemble suction systemand high pressure hose3.7 TEChNICAl DATA fINISh <strong>270</strong>Voltage :230 V AC, 50 HzFuses :16 A time-lagUnit connecting line :4 m long, 3 x 1.5 mm²Max. current consumptionhose heating :6.0 ADegree of protection : IP 541Acceptance capacity :1.3 kWMax. operating pressure : 25 MPa (<strong>250</strong> bar)Max. volume flow :2.9 l/minVolume flow at 12 MPa(120 bar) with water : 2.3 l/minMax. temperature of thecoating material : 43 °C3.6 TEChNICAl DATA fINISh <strong>250</strong>Voltage :230 V AC, 50 HzFuses :16 A time-lagUnit connecting line :4 m long, 3 x 1.5 mm²Max. viscosity :Empty weight pump :Hydraulic oil fillingquantity :Max. vibration at the spraygun:Max. sound pressure level:15,000 mPas29.5 kg0.65 literlower than 2.5 m/s²74 dB (A)*Max. current consumptionhose heating :4,6 ADegree of protection : IP 54Acceptance capacity :1,1 kWMax. operating pressure : 25 MPa (<strong>250</strong> bar)Max. volume flow :2.2 l/minVolume flow at 12 MPa(120 bar) with water : 1.8 l/minMax. temperature of thecoating material : 43 °C*Place of measurement: 1 m distance from unit and 1.60m above floor, 12 Mpa (120 bar) operating pressure,reverberant floorMax. viscosity :15,000 mPasEmpty weight pump :28 kgHydraulic oil fillingquantity :0.65 literMax. vibration at the spraygun: lower than 2.5 m/s²Max. sound pressure level:74 dB (A)**Place of measurement: 1 m distance from unit and 1.60m above floor, 12 Mpa (120 bar) operating pressure,reverberant floor38