D30<br />

298<br />

boxer monoemissione - single emission<br />

proiettori<br />

spot lights<br />

emissione a fascio estensivo/stradale -extensive/road emission<br />

D30/RSHPS70E D30/RSHPS70E<br />

cd/klm<br />

80<br />

160<br />

240<br />

90°<br />

60°<br />

6m<br />

4<br />

2<br />

25<br />

45<br />

55<br />

15<br />

35<br />

5<br />

320 30°<br />

0<br />

2<br />

10 8 6 4 2 0 2 4 6 8 10m<br />

distribuzione isolux al suolo - apparecchio h 4.5m<br />

isolux distribution on ground - fixture height 4.5m<br />

D30/RSMH150E<br />

cd/klm 90°<br />

80<br />

120 60°<br />

180<br />

240 30°<br />

castaldi<br />

boxer/RS<br />

IP66 F 0,8m 03 - IK08<br />

D30/RSHPS70E-AL<br />

per sodio alta pressione<br />

for high pressure sodium<br />

70W E27 5900/6600lm<br />

D30/RSMH70E-AL<br />

per alogenuri metallici<br />

for metal halide<br />

per alogenuri metallici<br />

70W E27 6000/6900lm<br />

D30/RSMH150E-AL Osram<br />

for metal halide Osram<br />

150W E27 13300/14000lm<br />

D30/RSMH70G-AL<br />

per alogenuri metallici<br />

for metal halide<br />

70W G12 6600/7000lm<br />

D30/RSMH150G-AL<br />

per alogenuri metallici<br />

for metal halide<br />

per alogenuri metallici<br />

150W G12 12700/15500lm<br />

D30/RSMH250G-AL<br />

Philips CDM-T 250<br />

for metal halide<br />

Philips CDM-T 250<br />

250W G12 23000lm<br />

D30/RSMH150E<br />

12m<br />

4<br />

2<br />

8<br />

4<br />

0<br />

4<br />

20<br />

28 32<br />

12<br />

8<br />

6<br />

16<br />

24<br />

20 16 12 8 4 0 4 8 12 16 20m<br />

distribuzione isolux al suolo - apparecchio h 8m<br />

isolux distribution on ground - fixture height 8m<br />

D30/RSMH150G D30/RSMH150G<br />

cd/klm<br />

70<br />

140<br />

210<br />

280<br />

90°<br />

60°<br />

30°<br />

12m<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

2<br />

5<br />

10<br />

15<br />

25 20<br />

35 30<br />

40<br />

16 14 12 10 8 6 4 2 0 2 4 6 8 10 12 14 16m<br />

distribuzione isolux al suolo - apparecchio h 8m<br />

isolux distribution on ground - fixture height 8m<br />

D30/RSMH70E<br />

cd/klm 90°<br />

50<br />

150<br />

250<br />

60°<br />

30°<br />

D30/RSMH70G<br />

cd/klm 90°<br />

80<br />

160 60°<br />

240<br />

320 30°<br />

D30/RSMH70E<br />

6m<br />

5<br />

4<br />

15<br />

25<br />

2<br />

45 35<br />

55<br />

0<br />

2<br />

10 8 6 4 2 0 2 4 6 8 10m<br />

distribuzione isolux al suolo - apparecchio h 4.5m<br />

isolux distribution on ground - fixture height 4.5m<br />

D30/RSMH70G<br />

10m<br />

8<br />

6<br />

4<br />

2<br />

0<br />

2<br />

30<br />

4<br />

6<br />

10 14<br />

18<br />

26 22<br />

14 12 10 8 6 4 2 0 2 4 6 8 10 12 14m<br />

distribuzione isolux al suolo - apparecchio h 6m<br />

isolux distribution on ground - fixture height 6m<br />

D30/RSMH250G D30/RSMH250G<br />

cd/klm<br />

70<br />

140<br />

210<br />

90°<br />

60°<br />

12m<br />

8<br />

4<br />

45<br />

55<br />

65<br />

5<br />

15<br />

25<br />

35<br />

280 30°<br />

0<br />

4<br />

20 16 12 8 4 0 4 8 12 16 20m<br />

distribuzione isolux al suolo - apparecchio h 8.5m<br />

isolux distribution on ground - fixture height 8.5m<br />

508<br />

285<br />

166<br />

140<br />

445<br />

2