documentaţia tehnică.Caseta filmului, grila, placa frontală, colimatorul (cabluri incluse) camera de ionizare (cabluriincluse) vor fi alese. Toate piesele şi componentele fabricate vor fi vopsite in camp electrostatic.Braţul tubului (C-arm) şi componentele aferente pe standul TEMCO, vor fi dezvoltate înconformitate cu IEC 60601.Cuvinte cheie— Ordin 888 Bucureşti, Temco GRx-04, C-Arm, elevator stand, cameră radiografică.Abstract— According to the government resolution from 19.07.2006, the following were defined:Art. 1) Micro Radio Photography and Fluoroscopy are forbidden as radiological examination forpulmonary tuberculosis.Art. 2) For the enquiry of the pulmonary tuberculosis the execution of pulmonary standardradiography is allowed în case of suspicion of pulmonary tuberculosis, instead of obligatoryclinical examinations…This resolution resulted that the MRF systems (22 units) installed în Romania having to be shutdown. în cooperation with the company TEMCO the author of this document has worked out asolution by means of which the MRF systems can be modified. The concept was putted forward tothe Romanian government.The government arranged an auction. The company TEMCO won the competition of the auctionand received the order for the modification. The modification of the MRF systems meant a newdesign according to the directives for medicine products and according to the quality systems.The following specification was worked out: It has to be designed and developed a new unit forthe purpose of fixing the bucky, X-ray tube, collimator and cables. The focus between X-ray tubeand bucky should be 150 cm and as agreed an interface will be designed and installed between thetube arm and the elevator stand. The manufacturer will provide TEMCO with:cable duct for the current cable set.holding arm for the X-ray tube and collimator (tube arm)sheet metal box for positioning two switches that control the lift carriage movementall the necessary documentsBucky, grid, front plate, collimator (cabling included), ionization chamber (cabling included) will beselected kept? All the manufactured parts and items will be painted with powder. Tube arm and theaccompanying components will be tested on the TEMCO elevator stand according to IEC 60601.Keywords— Ordin 888 Bucuresti, Temco GRx-04, C-Arm, elevator stand, radiographic roomINTRODUCERELa procedurile radiografice (denumite şi “radiografie Bucky standard”) corpul pacientului estepenetrat de radiaţii. Pe partea opusă, radiaţia este î<strong>nr</strong>egistrată cu materiale potrivite şiconvertită într-o imagine. Această imagine arată ţesuturile prezente în calea radiaţiei: oaseleabsorb mai multă radiaţie decît ţesuturile moi şi sunt astfel umbrite. Ţesuturile cu aer, cum suntplămînii, sunt relativ permeabili astfel încît în spatele lor este î<strong>nr</strong>egistrat un nivel mai ridicat deradiaţie. Deoarece în general ţesuturi diferite se suprapun pe traseul razelor X, este de multe oriutilă realizarea mai multor imagini, din diferite direcţii. Mai mult de 30% din toate radiografiilerealizate, sunt expuneri ale toracelui [5]. Ca o regulă, expunerile toracelui sunt realizate în spaţiiradiografice separate. Mişcarea verticală este realizată de un motor controlat. Cursa braţului C-arm este suficient de mare încît pot fi examinaţi copii şi adulţi aşezaţi sau în picioare.A. SISTEMUL DE RADIOGRAFIE STANDARDÎn principiu sistemul de radiografie standard constă prin faptul că se foloseştedispozitivul Potter-Bucky cu grilă antidifuzoare.8

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!