20 Installation (for qualified installers only)<br />

Electrical Connection (required)<br />

• The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified<br />

installer and must meet all local codes.<br />

• Make sure the household breaker is shut off prior to working on any electrical lines.<br />

• The appliance, when installed, must be electrically grounded in accordance with local codes or, in the<br />

absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code,<br />

CSA C22.1.<br />

• The electrical line must be a min. 14 gauge, and supply 120 Volts at 60 Hz (2 Amps)<br />

Caution : Label all wires prior to disconnection when servicing controls. Wiring errors can cause<br />

improper and dangerous operation.<br />

Junction Box Assembly<br />

Grounded 110V<br />

Power Supply<br />

Grounded Receptacle<br />

Strain Relief<br />

Left Side of <strong>Fireplace</strong><br />

Receptacle Cover Plate<br />

Travis Industries 4070620 100-01188_000