26 Installation (for qualified installers only)<br />
Diffuser Plate Adjustment<br />
Certain vent configurations require the diffuser plate to be adjusted (refer to the approved vent<br />
configuration charts for details). Position # 1 is stock (bent). Position # 2 is flattened. See the directions<br />
below to change the diffuser to position #2.<br />
DIFFUSER SIDE VIEW<br />
Before (Stock - Position # 1)<br />
After (Position # 2)<br />
Firebox Roof<br />
Back Wall of Firebox<br />
<br />
<br />
<br />
1/4" Nutdriver<br />
Remove the exhaust<br />
restrictor.<br />
1/4" Nutdriver<br />
Remove the diffuser.<br />
Bend the round portion of the<br />
diffuser so it is flat (position # 2).<br />
Secure the flattened<br />
diffuser plate with the<br />
screws removed earlier.<br />
Replace the exhaust<br />
restrictor (see “Exhaust<br />
Restrictor Adjustment”<br />
for restrictor settings).<br />
Travis Industries 4070620 100-01188_000