24 Installation (for qualified installers only)<br />
Approved Vent Configurations<br />
Restrictor Position<br />
• Intake and exhaust restrictors are built into the appliance to adjust the flow rate of intake air and<br />
exhaust gases. Depending upon the vent configuration, you may be required to adjust the restrictor<br />
positions. The charts for acceptable vent configurations detail the correct vent restrictor positions.<br />
Exhaust Restrictor Adjustment<br />
If the diffuser is required to be in position # 2, you may wish to adjust the diffuser while the exhaust<br />
restrictor is removed.<br />
(closed) #6<br />
# 5<br />
# 4<br />
# 3<br />
# 2<br />
# 1<br />
(open - stock position) # 0<br />
Firebox RoofThe exhaust restrictor is shipped<br />
Back Wall of Firebox<br />
in postion # 0. If the restritor is<br />
required in a different postion,<br />
remove the screws, re-position<br />
the restrictor (see the illustration<br />
below), and replace the screws.<br />
In this example, the restrictor is<br />
set in position # 3.<br />
Back of Firebox<br />
Travis Industries 4070620 100-01188_000