30 Installation (for qualified installers only)<br />
Top Vent Configuration with Horizontal Termination<br />
• The termination must fall within the shaded area shown in the chart. Use the indicated restrictor and<br />
diffuser positions.<br />
• Up to four elbows (45° or 90°) may be used.<br />
• May use 8" or 6-5/8" diameter vent (see page for 22 details).<br />
• Only one horizontal elbow may be used.<br />
21' (max)<br />
5 feet<br />
0 feet<br />
0 feet<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Exhaust Restrictor # 6<br />
<br />
<br />
<br />
<br />
Intake Restrictor # 2<br />
<br />
<br />
<br />
<br />
Diffuser Position # 2<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
<br />
Exhaust Restrictor # 4<br />
<br />
<br />
<br />
Intake Restrictor # 2<br />
Diffuser Position # 2<br />
<br />
<br />
<br />
<br />
<br />
Exhaust Restrictor # 2<br />
<br />
<br />
Intake Restrictor # 1 (stock)<br />
<br />
Diffuser Position # 1 (stock)<br />
<br />
<br />
<br />
<br />
20 feet 20 feet<br />
15 feet<br />
10 feet<br />
0 feet<br />
This is considered a horizontal<br />
elbow (it does not matter<br />
whether it turns right or left).<br />
It may be a 90° or 45° elbow.<br />
5 feet<br />
5 feet<br />
H2<br />
H1<br />
Travis Industries 4070620 100-01188_000<br />
10 feet<br />
10 feet<br />
15 feet<br />
15 feet<br />
This is considered a<br />
vertical elbow<br />
20' (max)<br />
20' (max)<br />
Horizontal length is calculated by adding<br />
both lengths of horizontal run<br />
(Horizontal Length = H1 + H2).<br />
21' (max)<br />
15 feet<br />
10 feet<br />
5 feet<br />
0 feet