Abbildung 22: Disassembly of the fuse box<br />
Abbildung 23: Fuse<br />
open the ash–door and take out the burner–drawer, as described in chapter1.18.1 auf Seite 17.<br />
Next, lift the burner–pipe [8] carefully, pull it to the left and then remove it from the <strong>boiler</strong>.<br />
Subsequently, the end–piece of the down–pipe [7] should be taken out of the <strong>boiler</strong>. To do this, the<br />
tightening screw needs to be loosened. The end–piece can now be pulled out from the down–pipe. Lift<br />
out the burner–pipe overlay [10] from its position and remove it from the <strong>boiler</strong>. Then the burner overlay<br />
[11] needs to be lifted out of place and taken out of the <strong>boiler</strong> in a forwards motion.<br />
Finally, the ashtray should be taken out of the <strong>boiler</strong>. The remaining ash can be removed from the <strong>boiler</strong><br />
with a vacuum cleaner.<br />
After a thorough cleaning around the burner area, all parts need to be reassembled in reverse order.<br />
The pellet bin should be completely emptied during its half–yearly cleaning procedures. Any existing<br />
automatic filling facilities are to be switched off. The wood–powder, which is to be found in the pellet–<br />
bin, can be removed with the pellet bin–emptier [3] or with a vacuum cleaner.<br />
During the half–yearly cleaning procedures, the fuse element must also be checked and cleaned. To do<br />
this, loosen the tightening screw of the fuse box [6] and pull it through the hole in the fire pan and then<br />
out of the burner–drawer.<br />
After the service has been completed and the fuse element cleaned, the <strong>boiler</strong> has to be reassembled in<br />