28.04.2013 Views

pellets boiler - Paul Künzel GmbH & Co.

pellets boiler - Paul Künzel GmbH & Co.

pellets boiler - Paul Künzel GmbH & Co.

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

emoved with a vacuum cleaner from time to time. Do not forget to vacuum inside the ventilator case as<br />

well!<br />

After cleaning, the ventilator needs to be reassembled in reverse order.<br />

Caution: Be aware that during the first run after the cleaning, heavy dust could build up.<br />

If you have any questions or problems concerning your KUENZEL Pellet Boiler, please contact either<br />

your heating installer or your national KUENZEL agent. (See bf www.kuenzel.de).<br />

2 The KUENZEL Thermomix Valve<br />

Abbildung 26: Thermomix Valve Functions Diagram<br />

The KUENZEL Thermomix Valve is an automatic <strong>boiler</strong> back-end protection which does not require<br />

any other additional energy resources. The return-flow water, which comes out cold from the heating<br />

system, is pre-heated with hot flow-pipe water to a minumum of 63o C. This temperature is above the<br />

dew-point of the exhaust gas in the <strong>boiler</strong>, so that a build-up of condensation and premature damage of<br />

the <strong>boiler</strong> through corrosion can be avoided. The benefit of the <strong>boiler</strong> circulation pump (15) is not only<br />

for the bypass, but also as a loading facility for the buffer storage. The Thermomix Valve can be adjusted<br />

to match a <strong>boiler</strong> power of up to 50kW.<br />

<strong>Co</strong>nnections: In-put R 1 1/2“ , out-put R 1 1/2“˙A swivel-nut must fit the pump connection.<br />

Assembly: We recommend the installation with flat gaskets and stop valves at all three in-put points.<br />

This makes the service and maintenance easier because the whole system does not have to be emptied.<br />

The flaptrap of the Thermomix Valve must be kept shut when the system is being installed. If necessary,<br />

turn the inserted plastic part in the appropriate direction. Please be aware of the direction of the current!<br />

When the valve is being assembled, please use a pair of pliers.<br />

Service: Once a year, the valve must be opened up and cleaned. The expansion cartridge should be<br />

replaced after 5 years as a precautionary measure. If a fault occurs, all movable parts can be taken out<br />

using the lid at the side. This makes the cleaning and also the replacement of parts easier, as it saves<br />

having to take the whole Thermomix Valve out.<br />

24

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!