emoved with a vacuum cleaner from time to time. Do not forget to vacuum inside the ventilator case as<br />
well!<br />
After cleaning, the ventilator needs to be reassembled in reverse order.<br />
Caution: Be aware that during the first run after the cleaning, heavy dust could build up.<br />
If you have any questions or problems concerning your KUENZEL Pellet Boiler, please contact either<br />
your heating installer or your national KUENZEL agent. (See bf www.kuenzel.de).<br />
2 The KUENZEL Thermomix Valve<br />
Abbildung 26: Thermomix Valve Functions Diagram<br />
The KUENZEL Thermomix Valve is an automatic <strong>boiler</strong> back-end protection which does not require<br />
any other additional energy resources. The return-flow water, which comes out cold from the heating<br />
system, is pre-heated with hot flow-pipe water to a minumum of 63o C. This temperature is above the<br />
dew-point of the exhaust gas in the <strong>boiler</strong>, so that a build-up of condensation and premature damage of<br />
the <strong>boiler</strong> through corrosion can be avoided. The benefit of the <strong>boiler</strong> circulation pump (15) is not only<br />
for the bypass, but also as a loading facility for the buffer storage. The Thermomix Valve can be adjusted<br />
to match a <strong>boiler</strong> power of up to 50kW.<br />
<strong>Co</strong>nnections: In-put R 1 1/2“ , out-put R 1 1/2“˙A swivel-nut must fit the pump connection.<br />
Assembly: We recommend the installation with flat gaskets and stop valves at all three in-put points.<br />
This makes the service and maintenance easier because the whole system does not have to be emptied.<br />
The flaptrap of the Thermomix Valve must be kept shut when the system is being installed. If necessary,<br />
turn the inserted plastic part in the appropriate direction. Please be aware of the direction of the current!<br />
When the valve is being assembled, please use a pair of pliers.<br />
Service: Once a year, the valve must be opened up and cleaned. The expansion cartridge should be<br />
replaced after 5 years as a precautionary measure. If a fault occurs, all movable parts can be taken out<br />
using the lid at the side. This makes the cleaning and also the replacement of parts easier, as it saves<br />
having to take the whole Thermomix Valve out.<br />