auf Seite 27.<br />

Abbildung 4: The 4 places of attachment<br />

The connection of the flow and return must be set up so that they cross each other, in order to avoid a<br />

short–circuit of the current. Caution: When choosing the flow connecting pieces, pay attention to the<br />

fitted position of the ventilator! If the ventilator has been assembled with the exhaust gas escape pointing<br />

to the right, the right flow connecting pieces would be hidden and, therefore, would be unable to be used.<br />

1.11 Assembly of the Ventilator<br />

The ventilator is fitted to the exhaust gas excape nozzle on the rear side of the <strong>boiler</strong>. Push the ventilator<br />

onto the nozzle. The fan can then be turned so that the exhaust gas escape can be optionally positioned<br />

facing the right, left, the top or bottom.<br />

Now assemble the smoke pipe and adjust the exhaust gas facility. Then the ventilator should be fixed to<br />

the nozzle with the three clamp–screws.<br />

You must make sure that the exhaust gas system is leak–proof, as otherwise under bad conditions<br />

smoke gas could escape!<br />

Make sure that the space where the flue–pipe is, between the ventilator and the chimney, can still be<br />

reached for cleaning purposes.<br />