Abbildung 2: Boiler and integrated pellet storage bin are transported separately<br />
integrated pellet storage bin is detachable. In this way, it is also possible to carry the <strong>boiler</strong> down narrow<br />
cellar steps.<br />
When setting up, the local regulations and guidelines regarding installation in <strong>boiler</strong> rooms should be<br />
observed.<br />
Setting up the pellet <strong>boiler</strong> and the pellet storage must only take place in a dry, frost–proof authorized<br />
room. A sufficient ventilation regulation in the <strong>boiler</strong> room has to be made sure.<br />
For setting up the <strong>boiler</strong>, a level and adequately load–bearing floor is sufficient. If, however, a pedestal<br />
has to be used, it should be the same size or slightly bigger than the <strong>boiler</strong> itself.<br />
1.8 Separating the Boiler from the Integrated Pellet Bin<br />
So that the KUENZEL Pellet Boiler can be carried more easily into rooms which are difficult to access,<br />
one can separate the main body of the <strong>boiler</strong> from the pellet storage bin. This job can only be carried out<br />
by two men.<br />
To separate the integrated pellet bin from the <strong>boiler</strong>, these guidelines are to be followed:<br />
1. Loosen the pellet supply flange screws as shown in the picture and put them aside.3 auf Seite 7<br />
2. Loosen the screws at the four points of attachment as portrayed in picture ?? auf Seite ?? and put<br />
them aside.<br />
3. Now lower the pellet bin carefully from the flange.<br />
6