Standards :<br />

DIN 8555 : E 8-UM-300-CP (mod.)<br />

EN 14700 : E Fe10<br />

118<br />

<strong>UTP</strong> ANTINIT DUR 300<br />

Basic coated CrNi stick electrode for wear resistant<br />

surfacings in the armatures construction<br />

Application field<br />

<strong>UTP</strong> ANTINIT DUR 300 is suitable for wear and corrosion resistant surfacings on ferritic and austenitic<br />

base materials in the armatures construction. The extremely low Co-content permits the use in the nuclear<br />

area for claddings on valve seats.<br />

Properties of the weld deposit<br />

The weld deposit of <strong>UTP</strong> ANTINIT DUR 300 has a ferritic-austenitic structure in a ratio of approx.<br />

45 : 55 %. This alloy distinguishes itself by a high resistance against corrosive medias. It has also a high resistance<br />

against abrasion, cavitation and erosion. The ferritic-austenitic weld deposit is IK-resistant and has a<br />

low friction coefficient.<br />

Hardness of the pure weld deposit<br />

as-welding condition 310 HB<br />

after heat treatment 1 h / 550° C 380 HB<br />

Weld metal analysis in %<br />

C<br />

0,12<br />

Welding instruction<br />

Oxides must be removed in the welding area. Stick electrodes are weldable as vertically as possible with a<br />

short arc and in string bead technic. If one-layer-welding has to be made, pre-heating and interpass temperature<br />

have to be adjusted to the base material. If several layers are applied, the workpiece should be preheated<br />

to min 300 – 400° C. Pre-heating temperature should be maintained during the whole welding<br />

operation. Pay attention to an uniform and homogeneous temperature. The entired wear and corrosion resistance<br />

will be obtained on multi-pass applications. Re-dry stick electrodes 2 - 3 h at 250 - 300° C.<br />

Current type DC (+)<br />

Availability / Current adjustments<br />

Eledtrodes<br />

Amperage<br />

Si<br />

5,0<br />

* available on request<br />

Mn<br />

6,5<br />

Ø mm x L<br />

A<br />

P<br />

< 0,02<br />

S<br />

< 0,015<br />

Cr<br />

21,0<br />

Ni<br />

8,0<br />

Welding positions<br />

3,2 x 350*<br />

90 – 110<br />

Co<br />

< 0,15<br />

4,0 x 350*<br />

110 – 130<br />

Fe<br />

balance<br />

PA PB PC