ITech Centra Manual - ADSI
ITech Centra Manual - ADSI
ITech Centra Manual - ADSI
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Rubber Minimum Angle displays and sets the angle between consecutive vectors that<br />
when exceeded will invoke the tangential emulation mode. At angles less than the value<br />
set in this parameter the <strong>Centra</strong> will move between vectors without evoking the tangential<br />
emulation mode.<br />
Stencil Force is the force<br />
separation between drag<br />
knife mode and tangential<br />
emulation cut mode.<br />
Tangential emulation cut<br />
mode is normally used for<br />
rubber or very heavy<br />
material. The <strong>Centra</strong> will<br />
normally not cut this type<br />
of material so this value<br />
should be set to a high<br />
force %.<br />
5.9.6.4 Setup -> Line<br />
Sensor<br />
Clicking on Setup Line Sensor menu opens<br />
the SmartMark TM Menu.<br />
5.9.6.4.1 Line Sensor Tab<br />
Sensor Offsets - The SmartMark sensor is offset from<br />
the center of the knife. The sensor offset distance is<br />
preset at the factory or during installation, but may need<br />
to be adjusted on occasion. The <strong>Centra</strong> can<br />
automatically calculate and set the SmartMark offset<br />
and sensor size parameters. See drawing for definition<br />
of sensor offsets. See TSB Title Calibration Web Site<br />
Copy / CD Copy<br />
X/Y Sensor size is the offset from the exact center of the<br />
red dot of the SmartMark sensor to the sense radius and may change based on sensor<br />
sensitivity or media reflectivity. This parameter is best set using the procedure in the<br />
TSB above. The Sensor Size<br />
parameter is only useful in origin<br />
scale and three target scanning. If<br />
you are not using these methods you<br />
can set the size to 0.02 and the sensor<br />
size is included in the sensor-offset<br />
parameter.<br />
Scanning Parameters<br />
The <strong>Centra</strong> SmartMark system has<br />
adjustable scanning parameters to<br />
26